7.3 Water Full alarm

The inner water tray inside the air-conditioner has one water level safety switches, it controls

water level. When water level reaches an anticipated height, the water full indicator lamp lights up. (If

water pump is damaged, when the water is full, please remove the rubber blockage at the bottom of

unit, and all water will be drained outside.)

Summary of Contents for SLK-KY018-12KC/E

Page 1: ...able Air conditioner User s Manual R32 For Model SLK KY018 12KC E SLK KY018 14KC E Thank you for using our product Please read this user s manual carefully to ensure proper use maintenance and installation ...

Page 2: ... Name of Parts 3 3 Accessories 4 4 Appearance and Function of Control Panel 5 5 Appearance and Function of Remote Control 6 6 Operation Introduction 7 7 Installation Explanations 10 8 Maintenance Explanations 15 9 Troubleshooting 16 ...

Page 3: ...er supply and move it slowly 8 To avoid the possibility of fire disaster the air conditioner shall not be covered 9 All the air conditioner sockets must comply with the local electric safety requirements If necessary please check it for the requirements 10 Children should be supervised to ensure that they do not play with the appliance 11 If the supply cord is damaged it must be replaced by the ma...

Page 4: ...ircuit should hold a current valid certificate from an industry accredited assessment authority which authorizes their competence to handle refrigerants safely in accordance with an industry recognized assessment specification 19 Servicing shall only be performed as recommended by the equipment manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried...

Page 5: ...Page 3 2 Name of Parts Fig 1 1 Louver 6 Drainage outlet 2 Control panel 7 Air outlet 3 Front panel 8 Power cord 4 Castor 9 Drainage outlet 5 Air inlet 2 Name of Parts ...

Page 6: ......

Page 7: ...odel A Power on off 3 Dehumidifying B Fan speed 4 Fan C Temperature up 5 Auto swing D Temperature down 6 Low fan speed E Operation mode 7 Medium fan speed F Timer on off 8 High fan speed 1 Sleep mode 9 Water full 2 Cooling 4 Appearance and Function of Control Panel ...

Page 8: ...exposed to direct sunlight 1 Power on off 2 Timer on off 3 Operation MODE 4 C F selector 5 Temperature up 6 Temperature down 7 LED display 8 Auto swing 9 Fan speed 10 Sleep mode 1 Receiver signal 2 Cooling 3 Dehumidifying 4 Fan 5 Auto swing 6 Timing 7 Timer on off 8 Sleep mode 9 Fan speed 10 Temperature display 5 Appearance and Function of Remote Control ...

Page 9: ... 2 As shown in Fig 5 and Fig 5a install the exhaust hose and adjust the window position well Fig 5 Fig 5a 3 As shown in Fig 6 Connect drain hose well only for using heating model 4 Insert the power cord into an grounded AC115V 60Hz socket 5 Press the POWER button to turn on the air conditioner Fig 6 6 Operation Introduction ...

Page 10: ...temperature 61 F 88 F Press the WIND button to select wind speed 6 3 Dehumidifying operation Press the Mode button till the Dehumidify icon appears Automatically set the selected temperature to current room temperature minus 2 F 61 F 88 F Automatically set the fan motor to LOW wind speed 6 4 Fan operation Press the Mode button till the Fan icon appears Press the WIND button to select wind speed 6 ...

Page 11: ...eases 2 F after 2 hours Press the SLEEP key again can cancel the setting 6 9 Water drainage Water Full Alarm The inner water tray inside the air conditioner has one water level safety switches it controls water level When water level reaches an anticipated height the water full indicator lamp lights up If water pump is damaged when the water is full please remove the rubber blockage at the bottom ...

Page 12: ...and the window Connector to the ends of the exhaust hose 2 Insert the fixing clip of the housing adaptor into the openings at back of the air conditioner 3 Put the other end of the exhaust hose to the near windowsill see Fig 9 Window Kit Installation The installation manner of window slider kit is mostly in horizontal or vertical As shown Fig 10 and Fig 10a check the min and max size of the window...

Page 13: ...Page 11 Fig 9 Fig 10 Fig 10a Fig 11 ...

Page 14: ... dimensions of the window Glue them to the frame of your window and then do the same on the inner surface of the window flap on the side of the handle 3 Glue the widest side A of the large white fabric piece to the window frame and then glue the narrower side B to the window leaf handle side from the center then up and finally down 4 Close the window and make sure the large fabric piece is not stu...

Page 15: ...level of the bottom or middle of the window then insert the exhaust duct into the opening Readjust the zipper so that the exhaust duct is attached so that there is no air exchange between the inside and the outside 6 Your caulking kit is now installed you can now turn on and enjoy the coolness of your mobile air conditioner If you no longer want to use your mobile air conditioner and close your wi...

Page 16: ...ne water level safety switches it controls water level When water level reaches an anticipated height the water full indicator lamp lights up If water pump is damaged when the water is full please remove the rubber blockage at the bottom of unit and all water will be drained outside ...

Page 17: ...e air filter becomes clogged with dust dirt the air filter should be cleaned once every two weeks Dismounting Open the air inlet grille and take off air filter Cleaning Clean the air filter with neural detergent in lukewarm 104 F and dry it up in the shade Mounting Putting the air filter into the inlet grille replace the components as they were 8 2 Clean the Air conditioner Surface First clean the...

Page 18: ... if possible Exhaust air hose is not connected or blocked Connect or clean the exhaust air hose Temperature setting is too high Reset the temperature Air inlet is blocked Clean the air inlet 3 Noisy The ground is not level or not flat enough Place the unit on a flat level ground if possible The sound comes from the flowing of the refrigerant inside the air conditioner It is normal 4 E0 Code Room t...

Reviews: