6.1. Before using
Notice:
-
Operation temperature range:
Check up whether the exhaust hose has been mounted properly.
Cautions for cooling and dehumidifying operations:
-
When using functions on cooling and dehumidifying, keep an interval of at least 3 minutes
between each ON/OFF.
-
Power supply meets the requirements.
-
The socket is for AC use.
-
Do not share one socket with other appliances.
-
Power supply is
AC115V/60Hz
6.2 Cooling operation
-
Press the “Mode” button till the “Cool” icon appears.
-
Press the “ DOWN ”or“ UP ”button to select a desired room temperature. (61°F-88°F)
-
Press the “ WIND ” button to select wind speed.
6.3 Dehumidifying operation
Press the “Mode” button till the “Dehumidify” icon appears .
-
Automatically set the selected temperature to current room temperature minus 2°F. (61°F-88°F)
-
Automatically set the fan motor to LOW wind speed.
6.4 Fan operation
-
Press the “Mode” button till the “Fan” icon appears.
-
Press the “ WIND ” button to select wind speed.
6.5 Heating operation (this function is not available for a cold-single unit)
-
Press the “Mode” button till the “Heat” icon appears.
-
Press the “ DOWN ”or“ UP ” button to select a desired room temperature. (61°F-88°F)
-
Press the “ WIND ” button to select wind speed.
Maximum cooling
Minimum cooling
DB/WB(°F)
95/75
64/54
Maximum heating
Minimum heating
DB/WB(°F)
80/---
45/---