Sineoji PL500EW User Manual Download Page 12

 

Try power cycling the unit by unplugging it from the wall for 10 seconds and plugging it in again. 

 

Hold  the security/reset button down for  more than 15 seconds  to  reset  to  default  setting.  The HomePlug  AV Ethernet 

Bridge’s light will flash, the units will reset and attempt to link using default factory settings. 

 

Try plugging the HomePlug AV Ethernet Bridge into an adjacent plug. 

 

HomePlug AV Ethernet Bridges work better when plugged directly into the wall outlet.  Connecting these Ethernet Bridges 

to a power strip or surge protector may degrade network performance or completely stop network signals. 

 

This HomePlug AV Ethernet Bridge should not be used on GFI protected outlets as some outlets will filter out HomePlug 

Powerline signal. 

 

This HomePlug AV Ethernet Bridge should not be used in areas with excessive heat. 

 

Certain florescent or incandescent lights are noise sources on the electrical and can degrade performance. 

 

If your building has more than one circuit breaker box, your HomePlug AV Ethernet Bridges may not be able to connect 

between the different circuit  breaker boxes.  In this case, connect one HomePlug AV Ethernet Bridge to a power outlet  

located on each of the circuit boxes.  Connect Ethernet cable between each of the HomePlug AV Ethernet Bridges to link 

the different circuits together.  This will allow the HomePlug AV Ethernet Bridges from different circuit breaker boxes to 

connect.   

 

To enter standby mode for this device, simply remove the Ethernet cable and wait about 3 minutes.   

 

4 Specifications 

 

PLC Module Specification 
Chip 

Qualcomm Atheros AR7420/AR1540 

Protocol 

HomePlug AV 
IEEE1901 
IEEE 802.3 10/100 Ethernet (100Mbps) 
IEEE 802.3u Fast Ethernet 

Powerline Communication Rate 

500Mbps 

Signal Band 

2~68MHz 

Modulation Mode 

Support OFDM 4096/1024/256/64/16/8-QAM, QPSK, BPSK, and ROBO 

Encryption 

128-bit AES 

Operation Mode 

Support priority-based CSMA/CA channel access scheme 

Multicast 

Support IGMP management multicast session. 

Wi-Fi Module Specification 
Chip 

Qualcomm Atheros AR9341 

Flash Memory 

64Mbps 

Summary of Contents for PL500EW

Page 1: ...User Manual PL500EW 500Mbps HomePlug AV 2 Port Wireless Range Extender...

Page 2: ...Safety CE This equipment is in compliance with the requirements of the following regulations CE Mark 89 336 EEC...

Page 3: ...tions Support channel self adaptation and channel estimation for maximizing real time throughput Support priority based CSMA CA channel access scheme for maximizing efficiency and throughput Support f...

Page 4: ...r today s HD Entertainment Center demand 1 1 Introduction Each HomePlug AV Ethernet Bridge allows you to connect one device that has an Ethernet port to a Powerline network In operation the HomePlug A...

Page 5: ...interface Off No connection is established via the LAN1 interface LAN2 Green On Connection via the LAN2 interface succeeds Green Blink Data is being transmitted via the LAN2 interface Off No connectio...

Page 6: ...or turn off the device 1 4 Initial Setup HomePlug is a plug and play device user is able to plug and play without any complex configuration and settings You can use HomePlug AV to connect networkable...

Page 7: ...s Bridge A and Bridge B are forming a new network Network AB The procedure is as follows 1 Press and hold the Security button on Bridge A for no more than 10 seconds Must release after 10 seconds Once...

Page 8: ...sh The password to Bridge C has just been erased and random security key has been generated It must now be linked to your network to adopt the new network security key 9 Press and hold the security bu...

Page 9: ...ower light on Bridge D starts to flash press and hold the Security button on Bridge B for 1 3 seconds then release 4 Bridge B and Bridge D are now connected to each other which in turn becomes part of...

Page 10: ...mouse click on the desired LAN and select PROPERTIES 7 Double click on INTERNET PROTOCOL VERSION 4 TCP IPv4 8 Select USE THE FOLLOWING ADDRESS 9 Enter the following IP address 192 168 33 X where X wi...

Page 11: ...s password ensure that you change the adapter settings to OBTAIN AN IP ADDRESS AUTOMATICALLY 3 Troubleshooting and Disclaimer If your HomePlug AV Ethernet Bridges have difficulty communicating with ea...

Page 12: ...de performance If your building has more than one circuit breaker box your HomePlug AV Ethernet Bridges may not be able to connect between the different circuit breaker boxes In this case connect one...

Page 13: ...tiation of PBC mode Consumption 6 5W Environment Requirements Operating Temperature 0 40 C Storage Temperature 10 70 C Operating Humidity 10 85 non condensing Storage Humidity 5 90 non condensing Rate...

Page 14: ...party hardware software programs data and or information stored on any media or any part of the Product no matter how occurring or for any loss or damage arising from loss of use loss of profits or r...

Reviews: