78
CH1
CH2
Note
Voltage(V)
+5.0Vdc
+24.5Vdc
Voltage
Region
Static mutual load
change and dynamic
load change
+4.75V~+5.25V
(-5%~+5%)
+22.05V~+26.95V
(-10%~+10%)
Average load
+4.75V~+5.25V
(-5%~+5%)
+22.78V~+26.22V
(-7.0%~+7.0%)
Output
Load
Condition
DC switch OFF
0.007A
-
-
Cover opens
0.25A
0.025A
Energy save
0.07A
-
-
Min. output current
0.25A
0.05A
-
Rated output
current
1.2A
4.7A
-
Max. output current
2.0A
(Maintains min. 30 min
operation)
5.7A
(Maintains min. 30 min
operation)
-
Peak output current
-
6.0A
-
2nd inrush
circuit(Surge
current)
20A
(Min. 50uS)
Total max. output
power
10W
140W
Static mutual load
change condition
5V min
–
24V nom
5V nom
–
24V min
Ripple and Noise Voltage
100mVp-p
300mVp-p
-
Overvoltage
Within voltage range
Within voltage range
-
Over
current
protection
Limit overcurrent
Fuse
7A ~ 10A
-
Recover method
Fuse replacement
AC reset
-
Protection operation
of shorted circuit
Block the power
Block the power
-
Overvoltage
Limit overvoltage
7V
30V
-
Recovery method
AC reset
AC reset
-
Summary of Contents for M611
Page 1: ...FIELD SERVICE MANUAL M611 M616 M612 M617 CS 2014 6 13 CE Confid ential...
Page 20: ...14 MFP Overview MFP Components...
Page 22: ...16 Paper Path 1 Output bin 2 Manual Tray 3 Base Unit Tray 4 Optional Tray Unit 5 Duplex Unit...
Page 43: ...37...
Page 88: ...82 3 24V Output Section...
Page 89: ...83 4 5V Output Section...
Page 90: ...84 5 AC Drive Section 6 Switching Section...
Page 91: ...85 Circuit HVPS Input Section 1 PWM Input Section...
Page 92: ...86 2 RCC Control Drive Section...
Page 93: ...87 3 High Power Output Section 4 TX SENSING...
Page 94: ...88...
Page 128: ...122 Removing Optional Acufeed Unit 1 Remove 2 harnesses and then 5 screws A...
Page 137: ...131 4 Separate the Exit frame with releasing the left and right side bolts...
Page 138: ...132 5 Release the harness bolts which are jointed to the fusing frame...
Page 157: ...151...
Page 214: ......