10
Maintenance
PM (Preventive Maintenance)
Customer Changeable Items
Items
Life Cycle
Toner Cartridge
Built-in : 3K (M611/M612), 6K (M616/M617)
Standard : 13K
Drum Unit
45K
Condition :
1. The above life cycle is measured based on 5% coverage on A4 size paper.
2.
Standard temperature and humidity
3.
The life cycle values are subject to change upon the envronment and printing
conditions.
Other Maintenance Items
Class.
Model Name
Parts
Life Cycle
M611/612 M611/M612/M616/M617
Fuser
120K
Tray Acufeed roller
120K
Transfer roller
120K
MPTSeparation Pad
30K
ADF Separation Pad
20K
The service life of the machine is 5 years or 100,000 sheets.
The above consumables should be complied with each replacement cycle since they may
directly affect the print images and the mechanical operations.
Summary of Contents for M611
Page 1: ...FIELD SERVICE MANUAL M611 M616 M612 M617 CS 2014 6 13 CE Confid ential...
Page 20: ...14 MFP Overview MFP Components...
Page 22: ...16 Paper Path 1 Output bin 2 Manual Tray 3 Base Unit Tray 4 Optional Tray Unit 5 Duplex Unit...
Page 43: ...37...
Page 88: ...82 3 24V Output Section...
Page 89: ...83 4 5V Output Section...
Page 90: ...84 5 AC Drive Section 6 Switching Section...
Page 91: ...85 Circuit HVPS Input Section 1 PWM Input Section...
Page 92: ...86 2 RCC Control Drive Section...
Page 93: ...87 3 High Power Output Section 4 TX SENSING...
Page 94: ...88...
Page 128: ...122 Removing Optional Acufeed Unit 1 Remove 2 harnesses and then 5 screws A...
Page 137: ...131 4 Separate the Exit frame with releasing the left and right side bolts...
Page 138: ...132 5 Release the harness bolts which are jointed to the fusing frame...
Page 157: ...151...
Page 214: ......