Air Source Heat Pump Water Heater
8
②
(**) Value obtained with an air temperature of 7°C and a water inlet at
10
℃
, as per EN16147, (EU) No 814/2013.
③
(***) Value obtained as per EN 12102-2008.
④
Under fast water heating mode, electric heater helps to heating water.
⑤
Please always see the nameplate for the exact data as this table is
subject to change.
Table 2-3 Water Tank Model and Specification
Model
SWH-200IRA2
Capacity
L
185
Power Supply for Electric Heater
-
220V-240V~50Hz
Input Power for Electric Heater
W
1500
Outline Dimensions(W x D x H)
mm
462 x 462 x 1944
Package Dimensions(W x D x H)
mm
583 x 583 x 2045
Water Tank Gross/Net Weight
kg
88/75
Outer Size of Connection Pipe
mm
Φ6, Φ9.52
Notes: Please always see the nameplate for the exact data as this table is
subject to change.
Table 2-4 Performance Data of Hot water Mode
Te
(℃)
Mode
inlet water T1
(℃)
outlet water T2
(℃)
capability
(kW)
COP
(W/W)
45
Hot
water
29
55
2.90
7.80
20
15
55
3.50
4.10
7
10
55
1.80
3.80
0
10
55
1.90
2.30
-7
10
55
2.40
2.20
-15
10
55
1.90
1.80
-20
10
55
1.40
1.50