11 MAINTENANCE AND UPKEEP
11.1 Failure information and code
In case the unit runs under abnormal condition, failure protection code will display on both control panel and wired controller,
and the indicator on the wired controller will flash with 1Hz. The display codes are shown in the following table:
Table11-1
SCV-300EB
and
SCV-600EB
Note
Recovered upon failure recovery
Recovered upon failure recovery
Recovered upon failure recovery
Recovered upon failure recovery
Recovered upon failure recovery
Recovered upon failure recovery
Recovered upon failure recovery
Recovered upon failure recovery
Recovered upon failure rcovery
Recovered upon failure recovery
NO.
1
2
3
4
5
6
8
9
10
12
13
14
16
17
19
20
21
22
23
24
25
26
27
28
Code
E0
E1
E2
E3
E4
E5
E7
E8
E9
Eb
EC
Ed
EF
EH
EP
EU
P0
P1
P2
P3
P4
P5
P6
P7
30
32
33
35
37
Inverter module failure
Water inlet and outlet temperature difference protection
Antifreeze protection in winter
Evaporator pressure too low in cooling
Cooling evaporator low temperature antifreeze protection
Main control parameter memory EPROM failure
Phase sequence failure of main control board check
Communication failure between master and the HMI
Total water outlet temperature sensor failure (main unit valid)
Unit water outlet temperature sensor failure
1E5 condenser tube temperature sensor T3A failure
2E5 condenser tube temperature sensor T3B failure
If there is a failure recovery,the
number of previous protections
will be cleared
Communication failure between master and slave
Recovered upon error recovery
Recovered upon error recovery
Recovered upon error recovery
Recovered upon error recovery
Recovered upon error recovery
Recovered upon error recovery
Recovered upon error recovery
Recovered upon error recovery
Recovered upon error recovery
Occurs 3 times in 60 minutes and
the error can be recovered by
turning off the power supply only
Occurs 3 times in 60 minutes and
the error can be recovered by
turning off the power supply only
Recovered upon error recovery
Recovered upon error recovery
Occurs 3 times in 60 minutes and
the error can be recovered by
turning off the power supply only
Occurs 3 times in 60 minutes and
the error can be recovered by
turning off the power supply only
Recovered upon error recovery
Occurs 3 times in 60 minutes and
the error can be recovered by
turning off the power supply only
Recovered upon error recovery
Recovered upon error recovery
Recovered upon error recovery
Recovered upon error recovery
Recovered upon error recovery
Content
T4 ambient temperature too high in heatling mode
Ambient temperature sensor failure
Slave unit module reduction
Unit water return temperature sensor failure
System self-check failure alarm
Discharge temperature sensor failure alarm
Tz/7 Coil final outlet temperature sensor error
System high-pressure protection or discharge
temperature protection
Tz/7 Coil final outlet temperature too high
System A current protection
High temperature protection of system condenser
1Eb-->Taf1 cooling evaporator low-temperature
antifreeze protection sensor failure
2Eb-->Taf2 cooling evaporator low-temperature
antifreeze protection sensor failure
1Ed-->A system discharge temperature sensor failure
2Ed-->B system discharge temperature sensor failure
Power supply phase sequence protector output error
Water flow detection failure
System low pressure protection
T4 ambient temperature too high in cooling mode
System B current protection
P9
Pb
PC
PE
PH
30