Sinclair RG51J1C User Manual Download Page 4

Model

Lowest Voltage of 
CPU Emitting Signal

Rated Voltage

8m (when using 3.0 voltage, 
it Gets 11m)

3.0V(Dry batteries R03/LR03

×

2)

2.0V

Remote Controller Specifications

1. Operating Mode:  AUTO, COOL, DRY, HEAT(Cooling & heating models only)
    and FAN.
2. Timer Setting Function in 24 hours.

O

O

3. Indoor  Setting  Temperature range: 17 C~30 C.
4. Full function of LCD (Liquid Crystal Display)

Environment

Signal Receiving 
Range

Performance Feature

Function buttons

CAUTIONS

Do not mix old and new batteries or batteries of a different type.
Do not leave the batteries in the remote controller if it is not going
to be used for 2 or 3 months.
Dispose of the old batteries in the special containers to be found
in the sales outlets.

1

TEMP UP Button    

 

Push this button to increase the indoor temper-
ature setting in 1 C increments to 30 C.

2

TEMP DOWN Button    

 

Push this button to decrease the indoor temper-
ature setting in 1 C increments to 17 C.

 Each time the button is pressed, the operation 
 mode is selected in the sequence of the following:
   
  

3

MODE  Button    

 

3

4

4

DIRECTION/SWING Button   

(For RG51Q models) 

  

 

 

 

SWING Button      

(For RG51Q(1) models)

       

6

5

7

RESET Button    

 

Once the recessed RESET button is pressed, 
all of the current settings will be cancelled 
and the controller will return to the initial settings.

8

ON/OFF Button    

 

Operation starts when this button is pressed 
and stops when the button is pressed again.

NOTE:  

Heat mode is for Cooling & Heating  models only.

AUTO

COOL

DRY

HEAT

FAN 

 

Used to select the fan speed in four steps: 

    Auto     Low     Med     High

   
  

FAN SPEED Button

 

  

 

 

    

 

NOTE:

 Med fan speed is not available for RG51J  

models .

O

-5 C~60 C

RG51Q/BG(C)E, 

RG51J(1)/(C)E, 

.

RG51Q1/BG(C)E, 

RG51IJ(1)/BG(C)E

            RG51Q/BG(C)E
            

            RG51Q1/BG(C)E
            

ADJUST

ADJUST

AUTO 
COOL
DRY
HEAT

AUTO 
COOL
DRY
HEAT

FAN
HIGH
MED
LOW

FAN
HIGH
MED
LOW

MODE

MODE

SWING

SWING

   AIR
DIRECTION 

FAN SPEED

FAN SPEED

DIRECTION

/SWING

SWING

TIMER ON

TIMER ON

ECO

ECO

ON/OFF

ON/OFF

TIMER OFF

TIMER OFF

RESET LOCK

RESET   C/H

2

1

4

5

5

6

3

7

8

9
10
11

SET TEMPERATURE(   C)

SET TEMPERATURE(   C)

12

Used to stop or start horizontal louver move-
ment or set the desired up/down air flow
direction. The louver changes 6 degree in 
angle for each press. If keep pushing more 
than 2 seconds, the louver will swing  up and 
down automatically.

SWING Button     

(For RG51Q1 models)

SWING Button 

(For RG51J models) 

Used to stop or start horizontal louver move-
ment .

  

Used to stop or start vertical louver move-
ment .

AIR DIRECTION Button 

(For RG51Q1models) 

Used to set the desired up/down air flow
direction. The louver changes 6 degree in 
angle for each press. 

  
  Buttons design might be slightly different from the actual one you purchased 
  depending on individual models. 
  All the functions described are accomplished by the indoor unit. If the indoor unit 
  has no this feature, there is no corresponding operation happened when press the 
  relative button on the remote controller. 

Note:

Summary of Contents for RG51J1C

Page 1: ...USER S MANUAL FLOOR CEILING SERIES ASF 60AN remote controller...

Page 2: ...he remote controller Remote controller Specifications Function buttons Indicators on LCD How to use the buttons Auto operation Cooling Heating Fan operation Dehumidifying operation Swing operation Tim...

Page 3: ...vent the sunlight from falling on the receiver If other electrical appliances react to the remote controller either move these appliances or consult your local dealer The remote controller is powed by...

Page 4: ...ot mix old and new batteries or batteries of a different type Do not leave the batteries in the remote controller if it is not going to be used for 2 or 3 months Dispose of the old batteries in the sp...

Page 5: ...peed in four steps Auto Low Med High FAN SPEED Button NOTE Med fan speed is not available for RG51J models RG51Q BG C E RG51Q1 BG C E ADJUST ADJUST AUTO COOL DRY HEAT AUTO COOL DRY HEAT FAN HIGH MED L...

Page 6: ...up to 10 hours then at 1 hour increments up to 24 hours To cancel the Auto off time setting just press the button until the time setting is 0 0 10 11 RG51J 1 C E TEMP AUTO COOL DRY HEAT MODE SWING FAN...

Page 7: ...e unit is operating Displays the selected fan speed AUTO HIGH MED if applicable and LOW Nothing displays when the fan speed is selected in AUTO speed When AUTO or DRY Mode is selected there will be no...

Page 8: ...anel of the indoor unit illuminates 1 Press the MODE button to select Auto 2 Press the TEMP button to set the desired temperature The temperature can be set O O within a range of 17 C 30 in 1 C increm...

Page 9: ...h press If keep pushing more than 2 seconds the louver will swing up and down automatically Press the SWING button the vertical louver will swing left and right automatically 2 For RG51J C E models wh...

Page 10: ...disappear and the set temperature will re appear on the LCD display window To set the Auto on time To set the Auto off time 1 Press the TIMER OFF button The remote controller shows TIMER OFF the last...

Page 11: ...ure is useful when you want the unit to turn on automatically before you return home The air conditioner will automatically start operating at the set time To start the air conditioner in 6 hours 1 Pr...

Page 12: ...s function is activated TIMER OFF Example h TIMER ON OFF h On Stop 2 hours later after setting Set To stop the air conditioner 2 hours after setting and start it again 10 hours after setting 1 Press t...

Page 13: ...erature Off Stop Start TIMER ON OFF h 2 hours later after setting 5 hours later after setting Set The timer setting TIMER ON or TIMER OFF that in sequence occurs directly after the set time will be ac...

Page 14: ...isposal station is located INFORMATION CONCERNING USED REFRIGERANT MEDIUM This unit is containing fluorinated gases included in the Kyoto protocol The maintanance and the liquidation must be carried o...

Reviews: