background image

9

10

Timer operation

press the TIMER ON button can set the auto-on 
time of the unit. And press the TIMER OFF button 
can set the auto-off time of the unit.

1. Press the TIMER ON button. The remote 
    controller shows TIMER ON, the last Auto-on 
    setting time and the signal "h" will be shown on 
    the LCD display area. Now it is ready to reset the 
    Auto-on time to START the operation.
2. Push the TIMER ON button again to set desired
    Auto-on time. Each time you press the button, 
    the time increases in 30 minutes increments, up 
    to 10 hours, then at 1 hour increments up to 24 
    hours. 
3. After setting the TIMER ON ,there will be a one-
    half second delay before the remote controller 
    transmits the signal to the air conditioner. Then,
    after approximately another 2 seconds, the 
    signal "h" will disappear and the set temperature
    will re-appear on the LCD display window.

 To set the Auto-on time.

To set the Auto-off time.

1. Press the TIMER OFF button. The remote 
    controller shows TIMER OFF, the last Auto-off 
    setting time and the signal "h" will be shown on 
    the LCD display area. Now it is ready to 
    reset the Auto-off time to START the operation.
2. Push the TIMER OFF button again to set desired
    Auto-off time. Each time you press the button, 
    the time increases in 30 minutes increments, up
    to 10 hours, then at 1 hour increments up to 24 
    hours. 
3. After setting the TIMER OFF ,there will be a one-
    half second delay before the remote controller 
    transmits the signal to the air conditioner. Then,
    after approximately another 2 seconds, the 
    signal "h" will disappear and the set temperature
    will re-appear on the LCD display window.

   The effective operation time set by the remote controller for the timer 
   function is limited to the following settings: 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 
   3.5, 4.0, 4.5, 5.0, 5.5, 6.0, 6.5, 7.0, 7.5, 8.0, 8.5, 9.0, 9.5, 10, 11, 12, 13,
   14, 15,16,17, 18, 19, 20, 21, 22, 23 and 24.

IMPORTANT

Example of Timer setting

TIMER ON

Start

Off

6 hours later

(Auto-on Operation)

The TIMER ON feature is useful when you want 
the unit to turn on automatically before you return 
home. The air conditioner will automatically start 
operating at the set time.

To start the air conditioner in 6 hours.
1. Press the TIMER ON button, the last setting of 
    starting operation time and the signal "h" will 
    show  on the display area.
2. Press the TIMER ON button to display "6.0h" on
    the TIMER ON display of the remote controller.
3. Wait for about 3 seconds and the digital display 
    area will show the temperature again. Now this 
    function is activated. 

TIMER ON

Example:

h

Set

ADJUST

AUTO 
COOL
DRY
HEAT

FAN
HIGH
MED
LOW

MODE

SWING

FAN SPEED

DIRECTION

/SWING

TIMER ON

ECO

ON/OFF

TIMER OFF

RESET LOCK

2

1

SET TEMPERATURE(   C)

Summary of Contents for RG51J1C

Page 1: ...USER S MANUAL FLOOR CEILING SERIES ASF 60AN remote controller...

Page 2: ...he remote controller Remote controller Specifications Function buttons Indicators on LCD How to use the buttons Auto operation Cooling Heating Fan operation Dehumidifying operation Swing operation Tim...

Page 3: ...vent the sunlight from falling on the receiver If other electrical appliances react to the remote controller either move these appliances or consult your local dealer The remote controller is powed by...

Page 4: ...ot mix old and new batteries or batteries of a different type Do not leave the batteries in the remote controller if it is not going to be used for 2 or 3 months Dispose of the old batteries in the sp...

Page 5: ...peed in four steps Auto Low Med High FAN SPEED Button NOTE Med fan speed is not available for RG51J models RG51Q BG C E RG51Q1 BG C E ADJUST ADJUST AUTO COOL DRY HEAT AUTO COOL DRY HEAT FAN HIGH MED L...

Page 6: ...up to 10 hours then at 1 hour increments up to 24 hours To cancel the Auto off time setting just press the button until the time setting is 0 0 10 11 RG51J 1 C E TEMP AUTO COOL DRY HEAT MODE SWING FAN...

Page 7: ...e unit is operating Displays the selected fan speed AUTO HIGH MED if applicable and LOW Nothing displays when the fan speed is selected in AUTO speed When AUTO or DRY Mode is selected there will be no...

Page 8: ...anel of the indoor unit illuminates 1 Press the MODE button to select Auto 2 Press the TEMP button to set the desired temperature The temperature can be set O O within a range of 17 C 30 in 1 C increm...

Page 9: ...h press If keep pushing more than 2 seconds the louver will swing up and down automatically Press the SWING button the vertical louver will swing left and right automatically 2 For RG51J C E models wh...

Page 10: ...disappear and the set temperature will re appear on the LCD display window To set the Auto on time To set the Auto off time 1 Press the TIMER OFF button The remote controller shows TIMER OFF the last...

Page 11: ...ure is useful when you want the unit to turn on automatically before you return home The air conditioner will automatically start operating at the set time To start the air conditioner in 6 hours 1 Pr...

Page 12: ...s function is activated TIMER OFF Example h TIMER ON OFF h On Stop 2 hours later after setting Set To stop the air conditioner 2 hours after setting and start it again 10 hours after setting 1 Press t...

Page 13: ...erature Off Stop Start TIMER ON OFF h 2 hours later after setting 5 hours later after setting Set The timer setting TIMER ON or TIMER OFF that in sequence occurs directly after the set time will be ac...

Page 14: ...isposal station is located INFORMATION CONCERNING USED REFRIGERANT MEDIUM This unit is containing fluorinated gases included in the Kyoto protocol The maintanance and the liquidation must be carried o...

Reviews: