Wired Controller XK19
4
3.3 Temperature Setting
Press ▲or ▼ to increase/decrease the preset temperature. If press either of them continuously, the
temperature will be increased or decreased by 1
℃
every 0.5s
,
as shown in Fig.6.
In the Cooling, Dry or Heating mode, the temperature setting range is 16
℃~
30
℃ .
In the Fan mode, the setting temperature is fixed at 26
℃
.
In the Auto mode, the setting temperature is unadjustable.
Fig.6
3.4 Fan Setting
Under the “On”/”Off” state of the unit, press Fan and then fan speed of the indoor unit will change
circularly as shown in Fig.7.
Fig.7
3.5 Timer Setting
Under the “On”/”Off” state of the unit, press Timer to set timer off/on.
Timer on setting: press Timer, and then LCD will display “xx.x hour”, with “hour” blinking. In this case,
press ▲or ▼ to adjust the timing value. Then press Enter/cancel to confirm the setting.
Timer off setting: press Timer, if LCD won’t display xx.x hour, and then it means the timer setting is
canceled.
Auto
Low
Middle
High