NOTE:
All the electrical work must be done by qualified personnel according to the local rules and this manual.
The rated voltage and the exclusive circuit must be used.
Leakage circuit-breaker must be installed.
Please use specified fuse.
If the power supply cord of the unit is damaged, it must be replaced by a special cord or assembly
available from the manufacture or its service agent.
The diameter of power cord should be large enough. Use the exclusive wire to replace the damaged wire.
Wiring work should conform to national standard.
All the power supply cord directly connected to the fixed wiring without plug, and must incorporated
a supply disconnection with have at least 3mm open contact seperation in each pol
e.
Install the indoor unit
1. When routing the piping and wiring from the left or right side of
the indoor unit, cut off the tailings from the pipe holder in neces-
sary (shown in Fig.5).
Through the hole when routing the wiring only.
Cut off the tailings l when routing both the wiring and
piping.
2.Wrap the piping and wiring and pull them through the cut-off-
tailings hole (shown in Fig.6).
3. Hang the 2 mounting slots of the indoor unit on the upper tabs
of the real panel and check if it is firm enough.
4.The height of the installed location should be 2.3m or more from
the floor.
Tailings2
Tailings1
Fig.5
(Fig.4)
Connection pipe
Wrapping tape
Fig.6
6.Reassemble the clampand wiring cover.
7.Recover the surface panel.
power supply cord
(type:H05vv-F3G2.5mm
2
)
brown
Hole
Pipe holder
Drain hose
Control cord
(Heat pump type
only)
Power connection cord
control cord (5
0.75)
(for CE stander5
1.0 )
For heat pump type only
terminal
wiring clamp
yellow-green
wiring cover
blue
red
Power connection cord
(type:H07RN-F4G2.5mm
2
)
wire clamp
wiring interface
Install the indoor unit
66162002
6
02 11 30 10 25
25