Sinclair AMC-15A User Manual Download Page 8

 

7

 

 
 
 
 

COOLING 

 

9

  It is recommended to start the unit early on hot days, thus avoiding heating up of the room.  

9

  This   unit has a self-evaporation function for condensation water, so that it is normally not necessary to 

empty the water tank in cooling mode. The drainage hose need not be connected. Please make sure that 
the outlet is closed with the rubber cap during operation.  

(This does not apply in the case of high air humidity. If the   unit operates in cooling mode for a longer period and especially at a time 

of year with high air humidity, the condensation tank may be full. The control lamp will remind you to empty the water. Refer to error 

message E4. In such a case, empty the water tank via the condensation water outlet. If continuous high air humidity is likely, it is 

recommended to drain the condensation continuously via the drainage hose.) 

 

COOLING IN INDOOR OPERATION  

The   unit stands in the room to be cooled. 

 

Connect the air hose and the air outlet grid to the   unit as displayed in the illustration; the air hose 
connection piece and air outlet grid need to be exchanged. 
 
 
 
 
 
 
 
 
 
 
 
 
The warm extract air must be emitted from the room via the air hose. This can be executed e.g. via a tilted 
window, a door or wall aperture. Make sure that no warm outside air can enter the room. For effective 
cooling, we recommend our selection of various accessories which reduce or prevent entry of warm air into 
the room. 
 
Place the function to “COOLING”. Set the target temperature using the temperature control. The settable 
temperature range is between 17 and 30 degrees target temperature. The   unit must only be used in an 
ambient temperature of maximum 32°C. 
 

Note: After switching on, or over, the ventilator operates, but the compressor only starts after the control lamp has flashed for three 

minutes. Cooling effect may require a further 10 minutes. Further information is available under the item, “Troubleshooting”.  

 

COOLING IN OUTDOOR OPERATION  

The unit is outside the room to be cooled.  
Connect the air hose and the air outlet grid to the unit as displayed in the illustration; the air hose 
connection piece and air outlet grid need to be exchanged. 
 
 
 
 
 
 
 
 
 
 
 
 
Place the unit in the shade if possible and in a cool place in order to increase efficiency and to avoid 
overheating. At an ambient temperature of over 32 degrees, the   unit may deactivate. If this occurs 
continuously, we recommend you temporarily use the INDOOR OPERATION of the   unit. We recommend 
that a drainage hose for condensation water be connected. 
 
 

Summary of Contents for AMC-15A

Page 1: ...USER S MANUAL AMC 15A MOBILE SERIES ...

Page 2: ...MOBILE AIR CONDITIONER AMC 15A USER S MANUAL ...

Page 3: ... CIRCULATION m h 450 COOLING AGENT R410a REMOTE CONTROL INCLUSIVE TIME SWITCH 0 24 STD DIMENSIONS mm WXDXH 300x505x778 NET WEIGHT 30 5 kg All figures are approx data Characteristics pursuant to current Norm EN 14511 Subject to alterations EASY TO OPERATE AND TO EASY TO MOVE AROUND 9 The unit can be moved easily on rollers from room to room 9 The air quantity can be adjusted via up to three ventila...

Page 4: ...cient minimum safety distance to each wall Fig 1 8 Despite the splash water protection you should not operate the unit in moist areas such as e g swimming baths or similar areas 9 The colour of the unit can change slightly due to direct solar radiation 10 The unit is equipped with a special thermal deactivation This protects the unit from overheating in extreme ambient conditions 11 Please place t...

Page 5: ... 6 Please wait at least 5 minutes after switching off the unit before switching it back on to ensure the compressor is not damaged 7 The compressor of the unit has a power demand of at least 7 amps Do not use any extension cable with this unit 8 The unit is designed for the cooling heating and dehumidification of inside rooms Other use is excluded 9 If the power cable is damaged it must be replace...

Page 6: ...ectively up to a minimum temperature of 15 C 5 LED DISPLAY The display shows the set temperature in operation By pressing the TEMP or TEMP switch the required target temperature is briefly displayed On pressing the TIMER switch the number of hours is briefly shown until activation or deactivation After each manual setting the display automatically shows the default temperature In the dehumidificat...

Page 7: ...ich the unit is to switch off ii After the flashing of the number of hours on the LED has stopped you can select the required function cooling heating dehumidification and the required temperature iii When the set number of hours has expired the unit switches on automatically If you press the POWER switch before the time has expired the Timer programming is deleted and the unit switches off 8 SLEE...

Page 8: ...ir hose This can be executed e g via a tilted window a door or wall aperture Make sure that no warm outside air can enter the room For effective cooling we recommend our selection of various accessories which reduce or prevent entry of warm air into the room Place the function to COOLING Set the target temperature using the temperature control The settable temperature range is between 17 and 30 de...

Page 9: ...ase make sure that the condesnation water outlet is closed with the rubber cap during operation In such a case proceed analogously to the emptying of the water tank in the cooling function 9 The heating function of the unit must not be operated at a room temperature of more than 23 C or less than 7 C The unit can also be operated with heating function if the outside temperature is lower than 7 C H...

Page 10: ... remote control The Comfort Control Kit set is additional accessories It is possible to buy it at the seller or supplier After switching on or over the ventilator operates but the compressor only starts after the control lamp has flashed for three minutes Cooling effect may require a further 10 minutes Further information is available under the item Troubleshooting DEHUMIDIFICATION Humidity is ext...

Page 11: ...n the unit for a day The smell will disappear after a while In the case of intensive odour development air the room Can I operate the unit WITHOUT the extract air hose No To achieve temperature adjustments surplus heat or coldness must be discharged At which intervals should the activated carbon filter of the unit be replaced To use the purpose of the filter fully it should be replaced every 6 mon...

Page 12: ...off and start it again after approx 30 minutes If the error occurs continuously the unit requires specialist inspection E4 Water tank full If the water tank is full the warning sign E4 appears in the display To restart operation of the unit please remove the plug of the condensation water outlet to allow water to leak out Please use an appropriate collection tank When the water has been completely...

Reviews: