Installation Instructions

 

Specifi cations are subject to change without notice  

Page 6

[email protected] | www.manrose.co.nz 

Distributed by Simx Limited

Inline Extraction Fan Kits - 150mm Std Profi le

Flexible duct

Internal grille

External grille

EC axial inline extraction fan
screwed to the joist

TYPICAL INSTALLATION

PUB01551 2001

9.  Make the electrical connection as follows:
 

 

Wiring of Standard Switching model FAN0101 (Diagram 1).

 

The fan can be connected to the light switch so that the fan will start when the light is switched on, or a dedicated fan switch (not supplied).  

 

The fan should not be accessible to a person using either the shower or the bath.

 

Wiring of Timer Switching model FAN0102 (Diagram 2).

 

The fan can be connected to the light switch so that the fan will start when the light is switched on, or a dedicated fan switch (not supplied). 

 

The fan should not be accessible to a person using either the shower or the bath.

 

NOTE: All wiring must be fi xed securely and the cable to the fan should be a minimum of 1mm

2

 in section in section. All wiring  

 

must comply with current regulations. This system should be installed by a registered electrician.

 
 

The timer mechanism supplied is a fully adjustable timer which is installed in the fl ush box. This means that the fan will run on for approx 

 

0-20 minutes depending on settings (see diagram 2 for wiring instructions, and also instructions included with FAN2444 timer).

 

NOTE: There is an adjustable 0-5 minute delay time setting for switching the fan on.

Recommended

mounting position

INSTALLATION

Summary of Contents for Manrose

Page 1: ...anrose inline extraction fan kit is designed for ventilation within a shower cubicle The high performance fan provides high levels of extraction and enables additional ducting to be added to this syst...

Page 2: ...for ventilation The Building Code is enshrined in law The New Zealand Building Code G4 has been changed This is supported by Acceptable Solution G4 AS1 Fourth Edition that specifies mechanical ventil...

Page 3: ...se of damage to the supply cord switch off the device and do not tamper with it Damaged supply cords must only be repaired or replaced exclusively by the manufacturer or by an appointed representative...

Page 4: ...manrose co nz www manrose co nz Distributed by Simx Limited Inline Extraction Fan Kits 150mm Std Profile ELECTRICAL CONNECTIONS BROWN BLUE LIVE EARTH NEUTRAL GREEN YELLOW F N TIMER FAN2444 LIVE NEUTR...

Page 5: ...nding slots in the black housing adjacent to the ends of the bridge piece in the housing 4 Select a suitable place for the fan to be screwed to a joist and secure using two screws through the fixing b...

Page 6: ...Switching model FAN0102 Diagram 2 The fan can be connected to the light switch so that the fan will start when the light is switched on or a dedicated fan switch not supplied The fan should not be acc...

Page 7: ...for a consequential loss or any other loss or damage caused to property or persons arising from any cause whatsoever b damage to consumable items such as lamps and starters and c damage arising from...

Reviews: