We strongly recommend this light fitting is installed by a registered electrician
Switch off the power supply before commencing any electrical work.
Unscrew the fixing screw at base, press top button down to release and remove the rear cover. Remove the
cable anchorage.
Use the rear cover to mark the position of screw holes onto mounting surface.
Drill the wall to depth of about 6cm and fit the wall plugs (supplied). Care should be taken to avoid drilling or
screwing into concealed electrical wiring/plumbing.
Push the round cable through the cable gland. Affix the rear cover to the mounting surface with mounting wall
screws (supplied). Connect the power cables to the terminal block securely (Fig 1).
Refit the cable anchorage and align the power supply pins. Re-attach and securely screw the light to the rear
cover while ensuring cables are not pinched when closing the unit.
Reconnect mains power. Test circuit and walk test.
INSTALLATION
OPERATION SETUP
Fig. 1
Control button is located on the rear of the PIR housing.
This light has 4 modes signified by the number of flashes with each press of the control button
=
Brown
=
Green / Yellow
=
Blue
Rear Cover
FLASHES
MODE
1
Light will only be triggered at night and will follow the movement of the subject triggering it.
2
Light will be triggered day and night and will follow the movement of the subject triggering it.
3
Light will only be triggered at night and will not follow the movement of the subject triggering it.
4
Light will be triggered day and night and will not follow the movement of the subject triggering it.