EN
15/28
Below tables show pre-programmed parameters. To modify them, refer to 6.3 paragraph (page 13). To make a more
advanced programming, refer to Expert parameters (page 18).
7.1 Generic parameters
d0
GENERIC PARAMETERS
Parameters
Value
Impulse 2BP
Mixed
Automatic
d1
Operating mode
00
Deadman
01
Mixed (automatic open / deadman close)
X
02
Impulse open and close
X
X
d2
AUX Command
configuration
00
Step by step command
X
01
Partial / complete opening selection for CMD1
02
Partial open command
X
03
Traffic management external command
04
Input photocell blanking
X
05
Automatic interlocking input
d3
Closing on
photocell activation
On
Closing after photocell activation
X
OF
No closing after photocell activation
X
X
d4
Closing on timer
end
On
Closing after end of the timer
OF
No closing after end of the timer
X
X
X
d5
With or without
clock system
On
With clock system
OF
Without clock system
X
X
X
d6
Number of closing
attempts
00
to
50
Closing attempts
03
00
03
d1
: Operating mode is preprogrammed during 1st power up procedure. It can be changed in deadman, mixed or
impulse. This mode is allowed only with necessary security devices.
d2
: Step by step command allows to control the shutter from a SIMU remote control (installation of the SAHz
receiver below).
Connection of SIMU radio receiver:
OUTPUT
24 VDC
Description
Reference
SA Hz standard receiver
2006380
Connections
B2:16
Receiver : 3
B2:17
Receiver : 4
B4:29
Receiver : 1
B4:30
Receiver : 2
SETTINGS IN LEVEL 1
7
Summary of Contents for SIMUDRIVE SD510
Page 28: ...www simu com ...