3.1.2
Safety edge operation
Activation of the safety edge when opening = disregarded, the door continues moving.
Activation of the safety edge when closing = stop + partial reopening.
3.2
Specific modes
Depending on the additional devices installed and the operating options programmed by your installer, the
motorisation may operate in the following specific ways:
3.2.1
Operation with a 3-button remote control
Up button
My button
Down button
Complete opening
Stop
Complete closing
STOP
3.2.2
Photoelectric cells operation
Cells obscured when opening = the state of the cells is disregarded, and the door continues to move.
Cells obscured when closing = stop + complete reopening.
3.2.3
Operation with orange flashing light
The orange light is activated 2 s before the door begins moving in sequential mode with automatic closure
after a time-delay.
3.2.4
Area lighting operation
The lighting comes on as soon as the motor starts and goes off 60 seconds after the motor has come to a
complete stop.
If a remote control is programmed to control the lighting, it operates as follows:
With a 2- or 4-button remote control
With a 3-button remote control
3.2.5
Operation in sequential mode with automatic closing after time delay
The door closes automatically after a time-out programmed during installation.