1. Delay Time
Only used in automatic functions such as the sun. The time length a condition
must be met before the control reacts.
(Min. 1minute - Max. 60 minutes)
2. Run Time
The length of time the 2200 will power the motor when it executes a
command. Note, should be set long enough to drive the motor to its limit and
the motor will still stop at its limit.
(Min. 1 second - Max. 240 seconds)
3. Sun Threshold
A programmed light level for the 2200 to react at . If the measured value from
The sun sensor exceeds the sun threshold for longer than the delay time, the
2200 will lower the window covering. If the measured value remains below the
threshold for the delay time, the 2200 will raise the window covering.
(Min. 1 klx - Max. 60 klx)
4. Tilt Time
A short up pulse given after the run timer ends in the down direction. This pulse
Is given to automatically tilt open some types of venetian blinds after closing.
Unless the 2200 is used with a tilt open blind the tilt time should be set to 0.0
(Min 0.0 seconds - 25.0 seconds)
5. Wind Threshold
A programmed wind speed for the 2200 to react at. If the measured value
From the wind sensor exceeds the wind threshold for longer than the delay
time, the 2200 will raise and lock in the up direction the window covering until
the wind Speed stays below the set threshold for longer than the set wind
release time
(Min. 1 mph - Max. 70mph)
6. Wind Release Time The time length the window covering will be locked up after the last measured
wind speed that exceeds the wind threshold.
(Min. 1 minute - Max. 59 minutes)
Unless the 2200 is used with a tilt open blind the tilt time should be set to 0.0
(Min 0.0 seconds - 25.0 seconds)