Configuration
All sensors are provided with default communication channels
and update rates. Refer to the table in section
About sensor
configuration
on page 14.
Adding a Spread/Depth sensor
In order to achieve full control of the trawl, you may wish to
add a Spread/Depth sensor on the port trawl door. This sensor
will communicate with the Remote/Depth sensor to establish the
distance between the trawl doors, and it will provide you with the
accurate depth of the port trawl door. The Spread/Depth sensor
will occupy one additional channel on your PI system.
Note
You will not be able to add a PI Spread/Depth sensor on a PI32
system.
Figure 7
PI44 Spread/Depth and Remote/Depth configuration
example
Sensor 1:
Demo mode:
Measure 1:
Measure 3:
- Update:
- Update:
DUAL
NONE
SINGLE
NONE
NONE
NONE
- Channel:
- Channel:
- Channel:
SPREAD
DEPTH 300M
DEPTH 300M
FAST
FAST
OFF
02
Sensor 2:
Measure 2:
16
17
Sensor 3:
Sensor 4:
Sensor 5:
Sensor 6:
Sensor setup
Accept
ENT
MENU
Exit
GAIN-
GAIN+
(CD012105C02)
This example shows how the PI44 (or PI54) is set up to receive
information from a PI Spread/Depth sensor (using two channels)
and a PI Remote/Depth sensor (using a single channel). Standard
communication channels and update rates are used.
To access the
Sensor Setup
menu:
1
Press the
MENU
button to open the main menu.
2
On the
Setup
menu, select
Sensor setup
.
3
Press the
ENT
button to allow for changes, and then the
same button one more time to accept the warning.
To set up the depth and distance (spread) readings from the PI
Spread/Depth sensor:
316870/A
13