Configuration
We recommend that you use the form at the beginning of the
PI32 Operator manual
to write down the sensors you have and
their respective communication channels and update rates.
Figure 5
PI Remote/Depth configuration example, PI32
2
11
FAST
FAST
Sensor 1:
SINGLE - Update:
SINGLE
Update:
-
NONE - Update:
Measure 1:
Measure 2:
Sensor 2:
Sensor 3:
Sensor setup:
(CD012103A04)
SPREAD - Channel:
DEPTH 300M - Channel:
This example shows how the PI32 is set up to receive information
from a PI Spread sensor and a PI Remote/Depth sensor. Standard
communication channels and update rates are used.
To access the
Sensor Setup
menu:
1
Press the
MENU
button to open the main menu.
2
On the
Setup
menu, select
Sensor setup
.
3
Press the
ENT
button to allow for changes, and then the
same button one more time to accept the warning.
• You must now use the circular navigation button to
move the cursor between the parameters, and the
+
and
-
buttons to select values.
To set up the depth readings from the PI Remote/Depth sensor:
1
Choose an available sensor; 1, 2 or 3.
2
Define the sensor type (by default
None
) to
Single
.
3
Set
Update
to the correct update rate.
4
Set
Measure
to the chosen sensor type
Depth 300M
,
Depth
600M
or
Depth 1000M
depending on the depth rating on
your PI Remote/Depth sensor.
5
Set the communication
Channel
to its correct value.
All sensors are provided with default communication channels
and update rates. Refer to the table in section
About sensor
configuration
on page 14.
Configuration of the PI44 and PI54
This procedure explains how to set up the PI44 and PI54 catch
monitoring systems to access the information provided by the PI
Remote/Depth sensor. For more detailed information about the
settings and parameters, refer to the relevant
Operator manuals
.
We recommend that you use the form at the beginning of the PI44
or PI54
Operator manual
to write down the sensors you have and
their respective communication channels and update rates.
316870/A
11