Simrad ITI
14
857-164777 / A
$IIMTW,-xx.x,C*hh<cr><lf> Water temperature at the trawl
MTW represents the Meteorological Temperature in the Water.
xx.x is the water temperature (
°
C) measured at the trawl.
(Sign prefix only if minus.) Range from -5
°
C to +30
°
C.
C means the value is in
°
Celsius.
- requires an active temperature sensor on the trawl.
@IIHFB,x.x,M,y.y,M<cr><lf>
Trawl Headrope to Footrope and Bottom (Trawl Eye/Height sensor 1)
HFB represents the distances from the Headrope to the Footrope and
Bottom.
x.x,M is the distance in metres from headrope to footrope (0 - 100 m).
y.y,M is the distance in metres from headrope to bottom (0 - 100 m).
@IIHB2,x.x,M,y.y,M<cr><lf>
Trawl Headrope to Footrope and Bottom (Height sensor 2)
HB2
represents the distances from the Headrope to the Footrope and
Bottom.
x.x,M
is the distance in metres from headrope to footrope (0 -- 100 m).
y.y,M
is the distance in metres from headrope to bottom (0 -- 100 m).
@IITDS,x.x,M<cr><lf> Trawl Door Spread 1
TDS represents the Trawl Door Spread 1 distance.
x.x,M is the spread distance in metres (0 - 300 m)
- if invalid, nullfields will be transmitted
- filtered values if sensorfilter is on.
@IITS2,x.x,M<cr><lf> Trawl Door Spread 2
TS2
represents the Trawl Door Spread 2 distance.
x.x,M is the spread distance in metres (0 -300 m)
- if invalid, nullfields will be transmitted
- filtered values if sensorfilter is on.
All manuals and user guides at all-guides.com