| 41
Technical specifications |
HS80/MX575C User Manual
(12) ZDA - Time and Date
UTC, day, month, year and local time zone
$GPZDA,hhmmss,xx,xx,xxxx,xx,xx*hh<CR><LF>
1 2 3 4 5 6
¼
Notes:
1
UTC
2, 3, 4
Day, month & year
5
Local zone hours, 00 to + 13 hrs
6
Local zone in minutes, 00 to +59.
(13) PCSI - Beacon Status Message
This message contains a variety of information relating to the status of Beacon engine inside
the MX575. The $PCSI,1 output message from the SBX beacon module is intelligently routed
through the MX575 to the port from which the $PCSI,1 message was requested.
$PCSI,CS0,PXXX-Y.YYY,SN,fff.f,M,ddd,R,SS,SNR,MTP,Q,ID,H,T
1 2 3 4 5 6 7 8 9 10 11 12 1314
¼
Notes:
1
Channel 0
2
Resident SBX-3 firmware version
3
SBX-3 receiver serial number
4
Channel 0 current frequency
5
Frequency Mode (‘A’ - Auto or ‘M’ - Manual)
6
MSK bit rate
7
RTCM rate
8
Signal strength
9
Signal to noise ratio
10
Message throughput
11
Quality number {0-25} - number of successive good 30 bit RTCM words
received
12
Beacon ID to which the receiver’s primary channel is tuned
13
Health of the tuned beacon [0-7]
14
$PCSI,1 status output period {0-99}