INSTALLATION
20222360 / E
33
Ethernet
The Processing unit can output data on Ethernet from terminal
J60. In the
Ethernet
submenu the IP address, net mask, IP port
number and output format have to be specified. For the NMEA
format the messages GGA, GLL, VTG, HDT, ROT and RRE are
included.
IP Address
:
Default setting: 192 168 001 020.
IP Net mast
:
Default setting: 255 255 255 000.
IP Port#
.
The IP port number, default is 5000.
Format
:
Format on Ethernet line. The following
selections are available:
o
NMEA
o
ZDA 1 Hz. See page 24 for discription of this
format.
o
STX104. A format used by service personnel
for troubleshooting the system.
o
None
WARNING!
If “None” is selected as output format, no data will be
sent to Ethernet line.
Caution!
A change in IP Address and IP Net mask parameter will not
take effect before the HS52 is restarted!
Summary of Contents for HS52
Page 4: ...Simrad HS52 GPS compass and DGPS navigator iv 20222360 E THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 8: ...Simrad HS52 GPS compass and DGPS navigator viii 20222360 E THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 48: ...Simrad HS52 GPS compass and DGPS navigator 40 20222360 E THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 73: ...FIGURES AND DRAWINGS 20222360 E 65 6 2 Processing Unit Dimensions ...
Page 76: ...Simrad HS52 GPS compass and DGPS navigator 68 20222360 E THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 78: ...Simrad HS52 GPS compass and DGPS navigator 70 20222360 E THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 79: ...APPENDIX B DECLARATION OF CONFORMITY 20222360 E 71 9 APPENDIX B DECLARATION OF CONFORMITY ...
Page 80: ...Simrad HS52 GPS compass and DGPS navigator 72 20222360 E THIS PAGE INTENTIONALLY LEFT BLANK ...