Assemble the Components
How to use the Quick-Connect (QC) fittings
The SimPure
®
T1-400 System uses quick-connect (QC) fittings making the
installation simple and easy.
How to release a tube from a quick-connect.
(1) Push the collet down onto the fitting (closing the gap between the collet and
fitting) and hold.
(2) While holding the collet down, gently pull the tube in the opposite direction
at the same time to release.
How to insert the tube into a quick-connect.
(1) Make sure the tube has a clean square cut with no bur present.
(2) Push the tube firmly into the QC fitting, making sure it is located correctly
(you will feel the tube 'jump' into position as you push it into the fitting).
The tube is secure once it has traveled
3
/
5
" (15mm) into the fitting.
Operation and Maintenance Guide
It is important to maintain the filters and RO membrane to ensure the outlet
water quality is a consistently high standard.
The life expectance of filters and replacement schedule is dependent on source
water quality and water consumption.
Under normal situations, we recommend users replace filters as per the table
below:
Note
:
When the flow of pure water is less than 0.5L/min, the filter cartridges
need to be replaced
If the pressure gauge shows more than 130PSI, the RO filter cartridge needs to
be replaced. Otherwise, you need to replace other filters
Replacement Filter Part Number
Part No.
Description
Replacement Schedule
(Months)
HEROF015_S2
PP Filter Cartridge
3-6months
HEROF016_S2
CTO Filter Cartridge
3-6months
HEROF017_S2
RO Filter Cartridge
12months
HEROF018_S2
T33 Filter Cartridge
3-6months
17
18