Water testing (Optional) 

To monitor the performance of your SimPure

®

 T1 Water Purification 

system, you will need a water meter that can test the impurities in 
water. SimPure

®

 has a simple to use handheld TDS meter designed for 

this purpose.  

It is recommended you follow the Monthly Maintenance procedure 
before taking a water sample: 

 

STEP 1 –

 OPEN the gooseneck faucet tap and run about one quart (1 

liter) to drain before sampling the water 

 

STEP 2

 – Rinse a clean cup or small container with the purified 

water and disregard, refill container. 

 

STEP 3

 – Place the SimPure

®

 TDS Meter in the solutions and follow 

the instruction to take a TDS reading 

 

STEP 4

 – Once you have a purified water reading, you should then 

test the feedwater. Run some water from your standard cold sink 
water tap into a clean cup or small container and test the TDS. 

Now that you have a water quality reading from the feedwater and the 
purified water, you can compare and see how well your water 
purification system is operating.  

As a general guide, the purified water TDS level should be >90% lower 
than the incoming feedwater indicating the system is working well; 
however, this does depend on feedwater quality, which can be 
substantially different from one region to another. 

 

 

 

 

 

Replacing Consumables 

It is important to maintain the filters and RO membrane to ensure the 
outlet water quality is a consistently high standard. 

The life expectance of filters and replacement schedule is dependent on 
source water quality and water consumption. 

Under normal situations, we recommend users replace filters as per the 
table below: 

Replacement Consumables Cartridges

 

Description 

Replacement 

Schedule 

(months) 

Part Number: 

PP Filter  

3 – 6 

RSWF012Z_M1 

(Kit of 5 Cartridges) 

GAC (UDF Filter) 

3 – 6 

CTO Filter 

3 – 6 

T33 Filter 

3 – 6 

ALK Filter 

3 – 6 

Reverse Osmosis (RO) 

for 75 GPD model* 

6 - 12 

RSRO004 

Reverse Osmosis (RO) 

for 100 GPD model* 

6 - 12 

RSRO005 

*Note: Depending on your system type order either the 75 or 100 GPD. 

 

 

25 

 

 

 

26

 

SimPure

®

 TDS Meter 

Part Number: 
RSTDS001_S8

 

Summary of Contents for 100GPD T1-6-100G

Page 1: ...oth smart easy to operate and practical in appearance and functionality SimPure products care for you your family our planet Stay simple Stay pure Contact Us If you require technical assistance please contact our friendly professional support engineers who will be pleased to assist you 3320 W Valley HWY North Ste D108 Auburn WA 98001 Phone 1 866 528 4572 Email info simpurewater com Web www simpure...

Page 2: ...sign from customer feedback clarified details added further instructions and diagrams 04 05 2020 Updated part number descriptions Table of Contents Overview 1 Getting Started 2 Introduction 2 Health and Safety 3 Operating Guidelines 4 Installation Guide 6 Installation Kit 7 Installation Guide 9 Plan your installation 9 Assemble the Components 11 Installing Cartridges 17 Plumbing the system 21 Flus...

Page 3: ...eliminate plastic bottles and protect our blue planet Please refer to the SimPure website for the latest product information including operator manuals videos support materials and where to purchase items The T1 6 is a durable piece of equipment with proper care it will last for many years This owner s handbook outlines the installation operation and maintenance requirements to sustain perfect pro...

Page 4: ...The following table lists the operating parameters for this product Operating this product outside these specifications may cause system performance issues and may even lead to personal injury and void any warranty Please contact SimPure for further advice and support Operating Parameters Model SimPure T1 6 Production rate up to Dependent on feedwater type operating pressure and water temperature ...

Page 5: ...installed over the sink Installation guide System Contents Your SimPure T1 RO Water Purification system was carefully assembled packaged and shipped complete with all the parts you should require for a standard installation Unsure about something Is there a problem Please contact SimPure through our website or toll free number Web www simpurewater com eMail info simpurewater com Toll Free Phone 1 ...

Page 6: ...WST001 H Gooseneck faucet HEWPRO007 I Housing wrench RO AWPA006 J Housing wrench filters AWPA007 K Tubing PE 16ft 5 Metres AWPA011 L Faucet mounting plate AWPA017 M Adaptor inline faucet tube QC AWPA018 N Valve water tank tube QC to thread AWPA009 O Locking C clips for QC fittings x8 AWPA008 P Valve saddle drain connection tube QC AWPA002 Q Valve male x female NPT thread AWPA003 R Bush red male co...

Page 7: ...system Option 1 Under sink The unit can be installed in a kitchen or bathroom sink cabinet A suitable drain point is required for drain water from the Reverse Osmosis system Option 2 Remote Interior The unit may also be installed in a remote interior location away from the RO Faucet You will need a nearby feed water source and drain point connection Check Space Requirements Determine and check the...

Page 8: ...mm into the fitting 3 Replace the locking C clips to secure the QC fitting Gooseneck Faucet Assembly SimPure T1 RO water purification system comes with a Gooseneck faucet which is used to dispense the purified water There are two methods for installation Fixing to the Sink Try to install the faucet on the sink surround if possible make sure you have clear access above and below and the outlet is o...

Page 9: ... electric drill Remove the backing and stick the saddle valve seal on the pipe line up the holes Assemble the drain saddle valve according to the picture below and tighten the bolts evenly with the cross head screwdriver to allow the clap to fit snuggly around the pipe Do Not Overtighten Once secure you can insert the PE tube into the saddle valve QC fitting 13 14 WARNING Never mount drain saddle ...

Page 10: ...ng bushes in your kit Note Please disregard the two x bushes if not required for your installation Water Pressure Tank Assembly The SimPure T1 Water Purification system comes complete with a water pressure tank to allow for a smooth and continuous output flow Wrap the threaded tank stem with Teflon tape and screw the valve onto the top of the tank hand tight only do not use any tools Only lightly ...

Page 11: ... Filter 5 micron 3 Pack RSIN002Z_3M1 F ALK Filter RSWPAL001 Please Note A SimPure T1 RO consumable kit is available which is shipped with 1 item of each filter except the RO membrane Please refer to the replacing consumables section for details when re ordering consumables The SimPure T1 is supplied with the T33 and ALK filters already in place you just need to load the RO membrane element and thr...

Page 12: ...Check the O ring inside the housing cap is in place and reassemble 8 Tighten the RO housing end cap using the wrench 9 Reconnect the PE tubing and C clip to the RO housing cap Please pay attention to the direction the RO element has to be installed or it will not function properly Pre Filter Housing Assembly Now we have the RO membrane element loaded we need to install the cartridge filters in the...

Page 13: ...re it does not leak Connect the other end of the PE tube to the QC on the 2 prefilter inlet Pressure Tank Connection Using the PE Tube and QC fittings connect between 3 inlet tee of the T33 filter and 4 the valve on top of the pressure tank Outlet Connection Using the PE Tube and QC fittings connect between 5 the outlet of the ALK filter and 6 the Gooseneck faucet connector Drain Connection Using ...

Page 14: ...ave completed the installation Please make sure the flush valve is CLOSED once the flushing is complete and when operating the system Operation and Maintenance guide Day to Day operation of the SimPure T1 The system is designed to purify feedwater continually until it has filled the 3 2 Gallon 12L pressure storage tank As water is drawn from the faucet tap the tank level drops and the system autom...

Page 15: ...e purified water you can compare and see how well your water purification system is operating As a general guide the purified water TDS level should be 90 lower than the incoming feedwater indicating the system is working well however this does depend on feedwater quality which can be substantially different from one region to another Replacing Consumables It is important to maintain the filters a...

Page 16: ...lon tape roll Replacement Parts SimPure replacement parts are available should you need to perform maintenance on your T1 system Replacement individual Parts Description Part Number X1 Prefilter housing O ring large AWPA025 X1 RO housing O ring small AWPA024 X3 Elbow tube QC to threaded AWPA021 X4 Elbow inline tube QC AWPA022 X6 Valve flush manual tube inline QC AWPA026 X7 Automatic shut off valve...

Page 17: ...ny part of the SimPure reverse osmosis water system that we find to be defective in operation due to faulty materials or workmanship within one year since the date of the original purchase Used replaceable filter cartridges and membranes are excluded General Conditions SimPure obligation to the customer under these warranties shall be limited at its option to replacement or repair of items covered...

Page 18: ... Test equipment helps monitor the performance of your SimPure water system making sure it s performing as expected SimPure Leak Detector automatically turns off the feedwater should your system develop a water leak Products SimPure products help to improve your life Air Purifiers to improve the air you breathe for your home and car Showerhead filters to improve your water quality and care for your...

Reviews: