7.3
Annual inspection
The following inspection should be carried out every 12 months, and the results recorded in
the log on the following page.
Annual Inspection Checklist
Category
No. Item
Check
General
1
Entire machine
Visually inspect for dented or broken parts.
Conduct a complete tipping cycle and check for
any faults or abnormal behaviour.
Hydraulic
systems
2
Hydraulic ram
Check there are no oil leaks.
3
Oil reservoir
Drain and replace the hydraulic fluid, in accordance
with the specifications in
Clean the intake suction-filter.
4
Lowering valve
Remove and clean.
Electrical
systems
5
Power lead
Check that the power lead is in good condition, with
no frayed or damaged insulation.
Safety
systems
6
Dual-hand
controls
Check that dual-hand controls operate correctly,
and machine stops instantly when SAFETY button is
released.
7
Safety Labels
Check that all warnings labels, guides etc are
attached and clearly legible.
Mechanical
systems
8
Mast and cradle
Not twisted or damaged.
No cracked or broken welds.
9
Inside mast
Lightly lubricate with silicone spray.
10
Pivot roller
11
Cradle axle
12
Tipping guide
flap
Check that flap is undamaged and moving freely.
13
Castor wheels
Check that the castor wheels are running smoothly
and both footbrakes are working correctly.