4. SPECIFICATIONS  

Big Genny and Big Genny Emergency Kit (EK) 

Dimensions 

22” L x 14” W x 9” H / 559 mm L x 356 mm W x 229 mm H 

Weight 

43 lbs. / 19.5 kg 

Charger Connection 

Neutrik 3 Pin XLR 

Big Genny and Big Genny EK’s Battery

 

DC Voltage - Nominal

 

12.8 Volts DC 

Amp-Hours

 

97 Ah 

Rated Watt-Hour Capacity

 

1,240 Watt-hours 

Operating / Charging Temperature

 

32°F to 104°F (0°C to 40°C) 

Battery Chemistry

 

Lithium Ferro Phosphate (LFP) 

Memory Effect

 

None 

Charge Retention

 

< 1% loss per month 

Charge Cycles

 

2,500 cycles 

Big Genny and Big Genny EK’s Inverter

 

Continuous Output Rating 

 

1,000 Watts 

AC Output Rating 

 

115 Volts AC +/- 5% / 12.5 Amps AC +/- 5%  

Frequency Rating

 

60Hz ±1  

Output Wave Form 

 

Pure Sine Wave 

DC Input Rating 

 

12 Volts DC / 100 Amps DC  

Input Voltage Range 

 

10.5 to 15.5 Volts DC   

Low Battery Alarm

 

10.5 Volts DC ± 0.5 VDC 

Low Battery Shutdown

 

10.0 Volts DC ± 0.5 VDC 

Over Voltage Shutdown

 

16.5 Volts DC ± 0.5 VDC 

No Load Current Draw

 

<1.0 Amp DC  

Optimum Efficiency 

 

>90%  

USB Output Rating 

 

5 Volts DC MAX / 2.1 Amps DC 

AC Output Sockets

 

2 x North American Standard Outlets 

Fuse Type 

 

100 Amp DC Auto-Reset Circuit Breaker   

Operating / Storage Humidity RH 

 

5 to 95%  

Cooling System 

Thermo Fan 

 

 

 

 

Summary of Contents for BIG GENNY

Page 1: ...www simpliphipower com techsupport simpliphipower com OPERATOR S MANUAL BIG GENNY...

Page 2: ...y Requirement 4 Getting Started Your Power Requirement 5 Operating a Microwave Oven with the Big Genny Power Inverter 5 Television and Audio Suggestions for Operation with the Big Genny Power Inverter...

Page 3: ...ce that can briefly spark when electrical connections are made or broken 4 Do not allow water or other liquids into contact with the inverter 5 Do not use the Big Genny with appliances with damaged or...

Page 4: ...prevent accidental pinching crushing abrading and tripping people 3 Use safety approved extension cords rated at 15 Amps or greater 4 The inverter included in the Big Genny is not tested for use with...

Page 5: ...d in the Big Genny has a rated capacity of 1 240 total Watt hours DC 1 116 Watt hours AC assuming a maximum inverter efficiency of 90 Connected loads consuming more energy than 1 116 Watt hours will r...

Page 6: ...s freezers and air conditioners These appliances can have startup loads of up to eight times the continuous rated Watts To ensure that the Big Genny is capable of powering the appliance at hand check...

Page 7: ...low the inverter to cool and then allow the battery to re charge before resuming normal operation USB Port This power port can supply 5 Volts DC at 2 1 Amps for charging or powering tablets e readers...

Page 8: ...ting range is between 11 and 15 Volts DC The inverter s low battery alarm will sound when the battery s voltage drops to 10 5V Push the momentary button located directly below the LCD Meter Fuel Gauge...

Page 9: ...rging 2 The inverter does not have to be ON to charge devices using the USB outlet 3 After the device is finished charging unplug the USB cable from inverter Charging using the Big Genny s Plug In AC...

Page 10: ...the portable solar module and orient it to fully face the sun 4 When the LCD Meter Fuel Gauge reads 14 6V a full battery charge has been reached 5 Remove the Neutrik connector by pulling upwards on th...

Page 11: ...fect None Charge Retention 1 loss per month Charge Cycles 2 500 cycles Big Genny and Big Genny EK s Inverter Continuous Output Rating 1 000 Watts AC Output Rating 115 Volts AC 5 12 5 Amps AC 5 Frequen...

Page 12: ...with regular Big Genny models Peak Output 200 Watts combined for the entire array MAX Output Voltage Vmp 18 Volts DC Open Circuit Voltage Voc 22 5 Volts DC MAX Output Voltage Vmp 18 Volts DC Open Circ...

Page 13: ...shut down GFCI LED is lit yellow The GFCI tripped Disconnect the connected loads Reset the inverter by turning OFF the ON OFF switch and then turning the switch back to ON Low battery alarm Battery vo...

Reviews: