Charging using the Big Genny Emergency Power Kit

’s Portable Solar Module 

The portable solar module is included with Big Genny EK models only; the solar module is not 
included with regular Big Genny models. 

 

1.  Ensure that the portable solar module is closed, so that the panels are not exposed to 

sunlight. 

2.  Connect the portable solar module to the Big Genny EK by inserting the yellow Neutrik 

connector into the DC IN / CHARGER port. After inserting the connector, turn it clockwise 
until it locks into place. 

3.  Open the portable solar module and orient it to fully face the sun. 
4.  When the LCD Meter Fuel Gauge reads 

14.6V

, a full battery charge has been reached. 

5. 

Remove the Neutrik connector by pulling upwards on the connector’s yellow tab and 
turning the connector counter-clockwise, then disconnecting from the Big Genny EK. 

 

The Big Genny EK can be used to power devices / appliances while the solar module is 
connected

. However, the Big Genny EK’s inverter would ideally be turned off while solar 

charging for quicker and more efficient battery charging. 

 

 

High Speed Cooling Fan 

When the temperature inside the inverter exceeds a preset limit, the Cooling Fan automatically turns on 
to cool the inverter. When the temperature reduces, the fan automatically turns off.   
 

 

 

DC IN / Charger port 

For Plug-In AC Charger OR 
Solar Module Connection 

Summary of Contents for BIG GENNY

Page 1: ...www simpliphipower com techsupport simpliphipower com OPERATOR S MANUAL BIG GENNY...

Page 2: ...y Requirement 4 Getting Started Your Power Requirement 5 Operating a Microwave Oven with the Big Genny Power Inverter 5 Television and Audio Suggestions for Operation with the Big Genny Power Inverter...

Page 3: ...ce that can briefly spark when electrical connections are made or broken 4 Do not allow water or other liquids into contact with the inverter 5 Do not use the Big Genny with appliances with damaged or...

Page 4: ...prevent accidental pinching crushing abrading and tripping people 3 Use safety approved extension cords rated at 15 Amps or greater 4 The inverter included in the Big Genny is not tested for use with...

Page 5: ...d in the Big Genny has a rated capacity of 1 240 total Watt hours DC 1 116 Watt hours AC assuming a maximum inverter efficiency of 90 Connected loads consuming more energy than 1 116 Watt hours will r...

Page 6: ...s freezers and air conditioners These appliances can have startup loads of up to eight times the continuous rated Watts To ensure that the Big Genny is capable of powering the appliance at hand check...

Page 7: ...low the inverter to cool and then allow the battery to re charge before resuming normal operation USB Port This power port can supply 5 Volts DC at 2 1 Amps for charging or powering tablets e readers...

Page 8: ...ting range is between 11 and 15 Volts DC The inverter s low battery alarm will sound when the battery s voltage drops to 10 5V Push the momentary button located directly below the LCD Meter Fuel Gauge...

Page 9: ...rging 2 The inverter does not have to be ON to charge devices using the USB outlet 3 After the device is finished charging unplug the USB cable from inverter Charging using the Big Genny s Plug In AC...

Page 10: ...the portable solar module and orient it to fully face the sun 4 When the LCD Meter Fuel Gauge reads 14 6V a full battery charge has been reached 5 Remove the Neutrik connector by pulling upwards on th...

Page 11: ...fect None Charge Retention 1 loss per month Charge Cycles 2 500 cycles Big Genny and Big Genny EK s Inverter Continuous Output Rating 1 000 Watts AC Output Rating 115 Volts AC 5 12 5 Amps AC 5 Frequen...

Page 12: ...with regular Big Genny models Peak Output 200 Watts combined for the entire array MAX Output Voltage Vmp 18 Volts DC Open Circuit Voltage Voc 22 5 Volts DC MAX Output Voltage Vmp 18 Volts DC Open Circ...

Page 13: ...shut down GFCI LED is lit yellow The GFCI tripped Disconnect the connected loads Reset the inverter by turning OFF the ON OFF switch and then turning the switch back to ON Low battery alarm Battery vo...

Reviews: