SimpliFire • SF-ALL40-BK, SF-ALL48-BK, SF-ALL60-BK, SF-ALL84-BK • 2040-981 Rev. M • 7/21
D. Location
Note:
If this unit is installed in a bathroom, it must be
protected by GFI receptacle or circuit. If receptacle is
used it must be readily accessible. This electrical ap-
pliance is not water tight. To prevent electrical shock, it
must be installed as to prevent water from entering unit. It
must be installed away from showers, tubs, or other water
sources. Never locate the appliance where it may fall into
a bathtub or other water container.
When choosing a location for your fireplace ensure that
the following general rules are followed:
• For best results, install out of direct sunlight.
• Power supply service must be installed within
proximity of electric fireplace prior to finishing to
avoid reconstruction.
• Appliance should be mounted so the front glass
panel is located outside the swing arc of adjacent
door.
• See Figure 3.2 and 3.3 to determine location of ap-
pliance installation.
E. Clearance to Combustibles
Minimum Clearance to Combustible Construction
Sides.......................0 in.
Floor........................0 in.
Top..........................0 in.
Back........................0 in.
Front..................... 36 in.
Mantel...................5/8 in.
See Figure 3.2.
F. Electrical Supply Circuit Requirements
Plan the location of the appliance so that it will have ad-
equate electric power. A 15 AMP, 120V/60Hz circuit is
required. Additional appliances on the same circuit as
this appliance may exceed the current rating of that cir-
cuit. A dedicated circuit is not required, but is preferred to
prevent circuit breaker trips or fuse failure.
min. 0 in.
min. 5/8 in.
Ceiling
Mantel
Floor
Wall
Outside
swing arc
of adjacent
doors
min. 0 in.
Figure 3.2 Location and Clearances Requirements
ELECTRICAL
OUTLET
LOCATION
Figure 3.3 Electrical Outlet Location
Note:
If mounting on a wall and using the supplied pow-
er cord, choose a location near an outlet so an extension
cord is not required.
WARNING! Risk of Fire!
Keep electrical cords, drapery,
furnishings or other combustibles at least 3 ft. (0.9 m)
from the front of the electric fireplace, and away from the
sides or rear.
12 in.
MAX
4 in.
MIN.
∞
MINIMUM 5/8 in. TO INSTALL /
REMOVE GLASS PANEL
UNLIMITED
Maximum Combustible and
Non-Combustible Mantel
Projections.