background image

 

 

 

 

 

 

 

Simplex Ethernet Clock 

Power Over Ethernet (POE)

 

 

                

 

                      

Installation Manual

 

Summary of Contents for 715437

Page 1: ...Simplex Ethernet Clock Power Over Ethernet POE Installation Manual...

Page 2: ...ion of this document to insure its accuracy Simplex assumes no liability resulting from any errors or omissions in this manual or from the use of the information contained herein 2006 Simplex 50 Techn...

Page 3: ...d Multiple Simplex Ethernet Clocks 4 Recording Location Static IP Address and Host Name 5 Section 3 Unpacking 7 Section 4 Installation Instructions 8 Surface Mounting 9 Pendant Mounting Single or Doub...

Page 4: ...four things that the clocks need from the network 1 A standard Ethernet connection using minimum CAT5 Cabling minimum up to 300 from the switch router 2 Power over Ethernet using the IEEE 802 3AF stan...

Page 5: ...your PoE capable LAN PoE Enabled Hub Switch In the simplest example the Ethernet is already PoE enabled 802 3AF and is supporting PoE devices such as IP phones Simply mount the Simplex Ethernet Clock...

Page 6: ...urrently PoE enabled and is going to support a single Simplex Ethernet Clock a Single Port Midspan Power Injector must be added to the 10 100 BaseT Ethernet LAN Note The power injector must be fully c...

Page 7: ...plex Ethernet Clocks a single or multiple Port Midspan Power Injector must be added to the 10 100 BaseT Ethernet LAN Note The power injector must be fully compatible with IEEE 802 3af Multi Port Midsp...

Page 8: ...stalled The Host Name will be visible in most DHCP servers It should describe the location so that the IP Address of a particular clock will be easy to locate by matching up the Host Name For example...

Page 9: ...CLOCK ID LOCATION IP ADDRESS Host Name 2007 Simplex Time Recorder Co All rights reserved Page 6...

Page 10: ...eb site Follow the directions in Section 4 for the desired mounting option A separate mounting kit model ONT4KIT or ONT6KIT for cantilever or pendant mounting is available Unpack the mounting kit and...

Page 11: ...tions The Simplex Ethernet Clock is available in a variety of mounting configurations Please consult the appropriate system documentation for your installation requirements 2007 Simplex Time Recorder...

Page 12: ...Surface Mounting The following is a recommended procedure for surface mounting No mounting kit is required 2007 Simplex Time Recorder Co All rights reserved Page 9...

Page 13: ...nts and tighten 4 Withdraw the fasteners until there is a 1 16 16cm gap between the mounting surface and the back of the fastener head 5 Insert the data cable into the jack located at the back of the...

Page 14: ...ipe or conduit If conduit is required it s a good idea to measure and cut to length before beginning the installation 1 Mark the location where the clock assembly is to be mounted making sure that the...

Page 15: ...the rear of the clock over the mounting tabs 6 Pull the clock slightly downwards until the unit is seated Repeat for the second clock if two clocks are being installed back to back 2007 Simplex Time...

Page 16: ...a 2 Phillips screwdriver and a 3 8 952 cm wrench assemble the Ethernet Clock Mount Simplex p n 714755 and the Ethernet Clock Cantilever Wall Mount Simplex p n 714756 as shown in the illustration in S...

Page 17: ...ata cable into the jack located on the back of the clock 6 Position the keyhole slots located on the rear of the clock over the mounting tabs on the clock mount 7 Pull the clock slightly downwards unt...

Page 18: ...dress 2 If the clocks are statically addressed record the IP Address and location of each clock in the table provided in Section 3 of this manual 3 If the clocks are DHCP addressed set and record the...

Page 19: ...date must be in the form of MMDDYYYYHHMMSS am pm Example to set March 17 2001 3 35 23 date 03172001033523pm OR date 03172001153523 Time values should always be in UTC GMT display Used to Configure an...

Page 20: ...telnet help both contain errors Use the online DST calculator at www buyinova com calculator to determine the correct eight 8 digit configuration rule for your location help Displays help information...

Page 21: ...Show all Interface data log Used to enable or disable logging and to print the log file to the session screen netstat Lists all TCP connections nslookup Displays the name or IP of the given argument...

Page 22: ...e 60 to 604800 Default 7200 secs t timeout Set the synch response timeout in microseconds Range 1000 to 120000 Default 10000 ms s Trigger an immediate SNTP Time Synchronization attempt stats Displays...

Page 23: ...ware tftp server the server to retrieve the update file from filename the file containing the new firmware code in tbin2 format user Configure and display the clocks user settings p password Sets the...

Reviews: