C - PROG menu : adjusting brightness, temperature and alternation
1. Enter the PROG menu (see page 6).
2. The brightness value blinks (from 1 to 3). Modify with the [+]
button. The brightness of the display is modified in real time.
3. Press the [S] button to validate the brightness and to go on to
the adjustment of the temperature offset.
4. The temperature offset blinks (from -9.5 to 9.5° in steps of
0.5°). Modify with the [+] button.
5. Press the [S] button to validate the offset and to go on to the
adjustment of the first alternation parameter.
6. The first alternation parameter blinks (h, t, d or -)*. Modify
with the [+] button.
7. Press the [S] button to validate the parameter and to go on to
the adjustment of the second alternation parameter.
8. The second alternation parameter blinks (h, t, d or -)*. Modify
with the [+] button.
9. Press the [S] button to validate the parameter and to go on to
the adjustment of the third alternation parameter.
10. The third alternation parameter blinks (h, t, d or -)*. Modify
with the [+] button.
11. Press the [S] button to validate the parameter and to go on to
the adjustment of the last alternation parameter.
12. The last parameter blinks (h, t, d or -)*. Modify with the [+]
button.
13. Press the [S] button to validate the parameter and to go on to
the adjustment of the alternation period.
14. The alternation period between information displays blinks
(from 2 to 6 seconds). Modify with the [+] button.
15. Press the [S] button to validate the alternation period. The
display returns to normal mode.
(*) h = time display t = temperature display date= date display - = no display.
Example of « h t d _ « setting : display of time, then temperature, then date, then return to time.
If «-» is selected, the next item of the information is displayed (no display in black). If the same letter is
entered twice in succession, the display time is doubled.