Temperature range
-20 °C at 100% battery
capacity up to +65 °C
(operation)
-40 °C to +70 °C (short-
term storage)
0 °C to +30 °C (long-
term storage)
Power supply
Via cylinder (3 V
DC
)
Standby: Up to 3 years
Activation Up to 32500
Radio emissions
SRD (WaveNet)
868 MHz - 870
MHz
10 dB (6,3 mW)
There are no geographical restrictions within the EU.
5. Declaration of conformity
The company SimonsVoss Technologies GmbH hereby de-
clares that article WN(M).LN.I.MP(.WP)/SI.LN.I.MP(.WP)
complies with the following guidelines:
2014/53/EU "Radio equipment"
5. Declaration of conformity
33 / 124 | EN