Outputs
relay:
or OC-type:
sensor power supply:
0, 1 or 2 NO 1A/250V AC (cos
j
= 1)
0, 1 or 2; 30mA / 30VDC / 100mW
24V +5%, -10% / max. 100 mA, stabilized
Communication interface
RS 485, 8N1 and 8N2, Modbus RTU,
not separated
Baud rate
1200 bit/s ÷ 115200 bit/s
Display
(depending on version)
LED, 4 digit, 13mm height, two-colour (red and green)
or (for IP 65 version) 5 digit, 9mm height, red
Data memory
non-volatile memory, EEPROM type
Protection level (depending on
display size)
5 x 9mm version: IP 65 (from front)
optional version with panel cut-out sealing available
IP 20 (housing and connection clips)
4 x 13mm version: IP 40 (from front)
IP 20 (housing and connection clips)
Housing type
Housing material
Housing dimensions
Mounting hole
Assembly depth
Panel thickness
panel
NORYL - GFN2S E1
72 x 36 x 97 mm
66.5 x 32.5 mm
min. 102 mm
max. 5 mm
Operating temperature
Storage temperature
0°C to +50°C
-10°C to +70°C
Humidity
Altitude
5 to 90% no condensation
up to 2000 meters above sea level
Screws tightening max. torque
0,5 Nm
Max. connection leads diameter
2,5 mm
2
Safety requirements
according to: PN-EN 61010-1
installation category: II
pollution degree: 2
voltage in relation to ground: 300V AC
insulation resistance
: >20M
W
insulation strength between power supply and
input/output terminal: 1min. @ 2300V
insulation strength between relays terminal:
1min. @ 1350V
EMC
according to: PN-EN 61326-1
This equipment is not intended for use in residential environments and may
not provide adequate protection to radio reception in such environments.