User manual - METER SRP-457
(see Info below),
„t Sh”
- the measuring range, this parameter has the fixed precision - 2-decimal point.
•
The unit value of “
t Sn
” parameter is 100-fold less than the unit value of
other parameters defining cylindrical tank, i.e. if we set value 10.00 in
“
t Sh
” parameter and set value 08.00 in "
t Sn
" parameter this mean that
value of “
t Sn
” parameter is real has 00.08 value in preserved unit of the
“
t Sh
” parameter.
•
If we set parameters of tank in [
m
] unit (“
t Sn
” parameter takes [
cm
] unit
respectively, see above), than displays the result the volume of the tank in
[
m
3
] unit, if we set parameters of tank in [
cm
] unit (“
t Sn
” parameter takes
[
mm
] unit respectively, see above), than displays the result the volume of
the tank in [
cm
3
] unit.
•
"
t Sh
" parameter may be greater than height (for vertical position) or
diameter (for horizontal position) of the tank, which means that the total
volume of the tank can be achieved by eg. such middle-current range,
•
If the measurement value do not exceeds permissible measurement range
but displayed value exceeds range of 9999 than you can move to the right
position of the decimal point if it is still possible (see parameter Menu-
>”
inPt
”->”
Pnt
”).
•
If in the volume characteristics of a cylindrical tank is exceeded the value
of the volume of the tank sets by parameters available in menu "
inPt
"
instead of the calculated result will be display warning “-Hi-”.
26