User manual - METER SRP-147-XC
Accepted prolonged input overload: 20%
Outputs
relay:
or OC-type:
sensor power supply:
active current:
0, 2 or 4 NO 1A/250V AC (cos
j
= 1)
0, 2 or 4; 30mA / 30VDC / 100mW
24V +5%, -10% / max. 100 mA, stabilized
range max. 0 ÷ 24 mA, load resistance max.700
W
(current output is optional, for two relays version only)
Communication interface
RS 485, 8N1 and 8N2, Modbus RTU,
not separated
Baud rate
1200 bit/s ÷ 115200 bit/s
Display
(depending on version)
LED, 4 digit, 38mm height, red or
LED, 4 digit, 38mm height, green
Data memory
non-volatile memory, EEPROM type
Protection level
IP 65
optional version with panel cut-out sealing available
Terminals protection
IP 20
Housing type
Housing material
Housing dimensions
Mounting hole
Assembly depth
Panel thickness
panel
NORYL - GFN2S E1
144 x 72 x 100 mm
138.5 x 67 mm
102 mm
max. 5 mm
Operating temperature
(depending on version)
0°C to +50°C
or -20°C to +50°C
Storage temperature
(depending on version)
-10°C to +70°C
or -20°C to +70°C
Humidity
Altitude
5 to 90% no condensation
up to 2000 meters above sea level
Screws tightening max. torque
0,5 Nm
Max. connection leads diameter
2,5 mm
2
Safety requirements
according to: PN-EN 61010-1
installation category: II
pollution degree: 2
voltage in relation to ground: 300V AC
insulation resistance
: >20M
W
insulation strength between power supply and
input/output terminal: 1min. @ 2300V
insulation strength between relays terminal:
1min. @ 1350V
EMC
according to: PN-EN 61326-1
5
Summary of Contents for SRP-147-XC
Page 50: ...User manual METER SRP 147 XC 50 ...