User manual - METER SRL-49
”tYPE”
- display mode of the bargraph, can be set to one of the values:
“LinE”
- the line of lighting LEDs (from position 0% to value depend on the
measurement result – in percent of full scale range)
“Pnt”
- the lighting point, single led indicates the percentage value of full scale range,
depend on measured value. Due to resolution of bargraph (5% of full scale),
only led closest to calculated value lights.
”FCoL”
- this parameter defines colours of the bargraph. Combination of red, green,
orange, and black ( dimmed segment) are used. Table 7.1 shows possible
combinations.
Value of „FCoL”
Bargraph colours
measurement
background
thresholds' markers
„bLAc”
The bargraph off
„grEE”
green
black
red
„rEd”
red
black
green
„g r”
green
red
orange
„r g”
red
green
orange
„b g”
black
green
red
„b r”
black
red
green
Tab. 7.1. Possible combinations of the bargraph colours
“Pr1P”
÷
“Pr4P”
- these parameters allows to define which one of the thresholds of the
relay will be showed on bargraph.
“oFF”
- no one thresholds will be marked,
“1St”
- threshold refer to
„SEtP”
, will be marked only
“2nd”
- threshold refer to
„SEt2”
, will be marked only
“botH”
- both thresholds will be marked.
“P1AL”
÷
“P4AL”
- these parameters allows to define
the critical situation of the
bargraph
depend on state of particular relays.
“noC”
- particular relay do not causes by critical situation on the bargraph.
“morE”
- critical situation will occur when measurement value will be greater than
threshold value
„SEtP”
of this relay,
“LESS”
- critical situation will occur when measurement value will be lower than
threshold value
„SEtP”
of this relay,
“on”
- critical situation will occur when particular relay will be closed,
“oFF”
- critical situation will occur when particular relay will be opened.
The critical situation of the bargraph
will occur in case when any of defined
situation occur.
The critical situation of the bargraph
is signalized by inverting of
colours (red to green, and green to red)
33
i
Summary of Contents for SRL-49
Page 60: ...User manual METER SRL 49 60...