User manual for universal counter with batching function SLIK-73
10.
DEFAULT AND USER'S SETTINGS LIST
Parameter
Description
Default value
User's value
Desc.
page
Parameters of relay R1 operation (“rELAy1” menu)
SEtP
Relay threshold
100
modE
Operation mode of relay
on
timE
The time period of the relay
active state
0.0
unit
Unit of
“timE”
parameter
SEC
Settings of programmable input, zeroing, filtering, and counting mode
Pr inP
Programmable input function
diSAbL
rESEt
Clearing (zeroing) source of main counter
ALL
ArESEt
Autoreset function
on
FiLtEr
Digital filtration rate
0
Funct
Counting mode
quAd-1
Prescaler settings (menu “PrESCA”)
muL
multiplier
1
div
divider
1
oFFSEt
Offset - constant value added to the result to move
the zero point of the current scale
0
Point
Decimal point position
0.00
RS 485 interface configuration (“rS-485” menu)
Addr
Device address
1
bAud
Baud rate
9600
mbAccE
Permission to changes of configuration registers
on
mbtimE
Maximum delay between received messages
0
rESP
Additional delay of answer transmission
Std
Settings of access to the configuration parameters (“SECu” menu)
A rEL
Permission to changes of relay R1 threshold
without of the user password knowledge
oFF
A oFFS
Permission to changes of the offset without of the
user password knowledge
oFF
Display parameters
briGHt
Display brightness
bri6
Configuration of numerical parameters edition
Edit
Numerical parameters edit mode
dig
40