![Simex Simpact SLIK-73 User Manual Download Page 16](http://html1.mh-extra.com/html/simex/simpact-slik-73/simpact-slik-73_user-manual_1275341016.webp)
User manual for universal counter with batching function SLIK-73
Allowable connection methods and counter configurations are showed in table 6.1.
used
counting input
”Funct”
parameter
“Pr inP”
parameter
state of
”C” input
B
”A - B”
”dirEct”
no active
B
”A - B”
other than ”dirEct”
any
A
”A - B”
”dirEct”
active
A or B
”A + B”
”dirEct”
active
A and B
”quAd 1” or ”quAd 4”
”dirEct”
no active
A and B
”quAd 1” or ”quAd 4”
other than ”dirEct”
any
B and A
”quAd 1” or ”quAd 4”
”dirEct”
active
Tab. 6.1. Possible configurations while use device as a batcher
Amount of poured fluid can be changed by parameter
“oFFSEt”
, which is showed first in
quick view mode, while parameter
“A oFFS” = “on”
(see page 30). Proposed in example
system is showed in Figure 6.2, and proposed circuit diagram in Figure 6.3.
More details of this example are described on page 33.
Figure 6.2. Proposed system
16
Flow detector
main valve,
controlled by relay R1
pulses to „B” input
tank