WIRING CONNECTIONS
Fire hazard.
Incorrect voltage can cause a fire or seriously dam-
age the motor and voids the warranty. The supply voltage must be within
±10% of the motor nameplate voltage.
NOTICE:
Dual-voltage motors are factory wired for 230 volts. If necessary,
reconnect the motor for 115 volts, as shown. Do not alter the wiring in sin-
gle voltage motors.
Install, ground, wire, and maintain your pump in compliance with the
National Electrical Code (NEC) or the Canadian Electrical Code (CEC), as
applicable, and with all local codes and ordinances that apply. Consult
your local building inspector for code information.
Connection Procedure:
Step 1. Connect the ground wire first as shown in Figure 6. The ground
wire must be a solid copper wire at least as large as the power sup-
ply wires.
Step 2. There must be a solid metal connection between the pressure
switch and the motor for motor grounding protection. If the pres-
sure switch is not connected to the motor, connect the green
ground screw in the switch to the green ground screw under the
motor end cover. Use a solid copper wire at least as large as the
power supply wires.
Step 3. Connect the ground wire to a grounded lead in a service panel, to a
metal underground water pipe, to a metal well casing at least ten
feet (3M) long, or to a ground electrode provided by the power
company or the hydro authority.
Step 4. Connect the power supply wires to the pressure switch as shown in
Figure 6.
You have just completed the wiring for your pump.
Please go to Page 9 for startup preparations.
For parts or assistance, call Simer Customer Service at
1-800-468-7867 / 1-800-546-7867
DISTANCE IN FEET(METERS) FROM MOTOR TO SUPPLY
0 - 100
101 - 200
201 - 300
301 - 400
401 - 500
Max. Load
Branch Fuse
(0 - 30)
(31 - 61)
(62 - 91)
(92 - 122)
(123 - 152)
Motor HP
Volts
Amp
Rating Amp
AWG WIRE SIZE (mm
2
)
1/2
115/230
9.4/4.7
15/15
14/14 (2/2)
10/14 (5.5/2)
10/14 (5.5/2)
6/14 (14/2)
6/12 (14/3)
3/4
115/230
12.2/6.1
20/15
12/14 (3/2)
10/14 (5.5/2)
8/14 (8.4/2)
6/12 (14/3)
6/12 (14/3)
Wiring Chart – Recommended Wire and Fuse Sizes