Electrical
7
For parts or assistance, call Simer Customer Service at
1-800-468-7867 / 1-800-546-7867
Disconnect power before working on pump, motor, pressure switch, or wiring.
Hazardous voltage. Can shock, burn, or kill.
Connect ground wire before connecting power supply
wires. Use the wire size (including the ground wire) speci-
fied in the wiring chart.
If possible, connect the pump to a
separate branch circuit with no other appliances on it.
Explosion hazard. Do not ground to a gas sup-
ply line.
Motor Terminal Board Connections:
Your Motor Terminal Board (under the motor end cover)
looks like one of those shown below. If necessary, convert
to 115 Volts as shown. Do not change motor wiring if line
voltage is 230 volts or if you have a single voltage motor.
Pressure Switch Connections:
Your Pressure Switch looks like one of those shown below.
Connect power supply as shown for your type of switch
and your supply voltage.
Figure 6A: Motor wiring connections through Pressure
Switch. Match motor voltage to line voltage.
Figure 6B:Wiring connections to Pressure Switch. Follow
instructions for your type of switch and your line voltage.
Pull plug
straight
out from
terminal
board.
1.
1.
2.
2.
Plug in again
with arrow
on plug
pointing to
'115 Volts'.
A
L1
230 V
olts
1
15
V
olts
A
L1
230 V
olts
1
15
V
olts
Ground
Screw
3962 0401 A
115 V
230 V
230 Volt to 115 Volt Conversion.
Move plug to change voltage.
Ground
Screw
230V
115V
230V
115V
A
A
L2
L2
L1
L1
230V
115V
A
A
L2
L2
L1
L1
230V
115V
Power Supply
Wires
230 Volt to 115 Volt Conversion.
Move plug to change voltage.
Clamp the power cable to prevent strain
on the terminal screws.
Connect the green (or bare copper) ground wire
to the green ground screw.
Motor wires
connect here.
Clamp the power cable to prevent strain
on the terminal screws.
Connect the green (or bare copper) ground wire
to the green ground screw.
Motor wires
connect here
.
3187 0398
Power supply wires
connect here.
230 Volt:
Connect 2 hot wires (black and red)
here and cap the white (neutral) wire. It does
not matter which wire goes to which screw.
115 Volt:
Connect one hot wire (black or red)
to one of these screws (it doesn't matter
which one). Connect the white (neutral) wire
to the other screw. Cap any remaining
black or red wires.
Power supply wires
connect here.
230 Volt:
Connect 2 hot wires (black and red)
here and cap the white (neutral) wire. It does
not matter which wire goes to which screw.
115 Volt:
Connect one hot wire (black or red)
to one of these screws (it doesn't matter
which one). Connect the white (neutral) wire
to the other screw. Cap any remaining
black or red wires.
Clamp power cable to avoid strain on terminals.
Connect the green (or bare copper) ground
wire to the green ground screw.
115 V
230 V
Power
Supply
Wires
L1
L2
230
11
5
L1
L2
230
11
5
L1
L2
230
11
5
Ground Screw
3994 0501
230 Volt to 115 Volt Conversion.
Move plug to change voltage.