73
TO SET THE HEATING AND SANITARY
WATER TEMPERATURE FROM THE
REMOTE CONTROL PANEL
The boiler temperature can be regulated at
intervals of 0.5°C by means of the keys
[SAN]
and
[RISC]
only when there is a con-
nection
The setting is memorised in the boiler and
remains independently of the remote con-
trol.
SET HEATING
SET SANITARY
Min Max
Min Max
PLANT WITH RADIATORS
40°C 80°C
35°C 60°C
[ + ] and [ - ]
: increase/decrease
(+/- 0.5°C) sanitary water temperature
[SAN]
: exit sanitary water temperature
setting
[ + ] and [ - ]
: increase/decrease
(+/- 0.5°C) heating temperature
[RISC]
: exit heating temperature setting
SET
: min = 6
T1 = 16 °C
T2 = 18 °C
T3 = 21 °C
manual = 21 °C
LANGUAGE
= Italian
TIME
= 0 - 24
PLEASE NOTE: To change the
value set for a level, see para-
graph “PROGRAMMING”
PROG: WINTER from MONDAY to SUNDAY
PROG: BETWEEN SEASON from MONDAY to SUNDAY
INITIAL PARAMETERS AND RE-MEMORISATION PROCEDURE
After pressing the key
(reset)
, see point “TO ENABLE RE-MEMORISATION” in paragraph “LANGUAGE/DATE/TIME REGULATION”; the fac-
tory parameters are reset, which are the same for both the winter and the between season programmes:
DISCONNECTION OF REMOTE CONTROL
The sanitary and antifreeze functions are guaranteed in any case, even if the remote control is disconnected.
From - to
Level
Value
00:00 - 06:00
T1
16 °C
06:00 - 09:00
T3
21 °C
09:00 - 12:00
T2
18° C
12:00 - 15:00
T3
21 °C
15:00 - 18:00
T2
18°C
18:00 - 22:00
T3
21°C
22:00 - 24:00
T1
16 °C
Fig. 9