8
1.2
Structure
Gi 20 Mar 2014
Zona 1
10:30
Modo: Inverno Progr. automatico - Set 18,0°C fino alle 11:30
Menu
Modo
1
2
5
4
3
7
6
8
16
17
14
19
13
12
11
10
E
9
15
U
Rpc
Mpc
Rbt
Mbt
G
OUT
IN
18
Fig. 2
KEY
1
150 litre domestic hot water storage tank
2
Plate heat exchanger (
Sp
)
3
Sensor socket
B1
4
Diverter valve (
VD
)
5
Domestic hot water pump (
PS
)
6
Domestic hot water expansion vessel (
Ve
)
7
Sensor socket
B2
8
Domestic hot water storage tank drain valve (
Rs
)
9
Domestic hot water relief valve (
Vs
)
10
Sensor
B3
11
System safety thermostat (
TS
)
12
Check valve (
Vr
)
13
Low temperature system pump (
PI
)
14
Inertial puffer
15
Electrical panel
16
Condensation boiler
17
Summer/winter selector
18
Heat pump Sime SHP M EV
19
Remote control
SIME HOME PLUS
E
Domestic hot water inlet (Ø 1/2”)
U Domestic hot water output (Ø 1/2”)
Rpc Heat pump return (Ø 3/4”)
Mpc Heat pump delivery (Ø 3/4”)
Rbt Low temperature system return (Ø 3/4”)
Mbt Low temperature system delivery (Ø 3/4”)
G
- Gas supply (Ø 3/4”)
IN Heat pump inlet (Ø 1”)
OUT Heat pump outlet (Ø 1”)