43
EN
3 SPECIFICATIONS
SIME FUEL
SIME FUEL 25 EV
(vers. std)
SIME FUEL 35 EV
(vers. std)
SIME FUEL 25 EV
(vers. HE)
SIME FUEL 35 EV
(vers. HE)
Heat output set in the factory
(1)
kW
27
34,8
26,2
34,8
kcal/h
23,220
29,928
22,532
29,928
Heat capacity set in the factory
(1)
kg/h
2,25
2,9
2,18
2,9
Fuel
(2)
Diesel, viscosity 1.6–6 mm
2
/s a (Hi=12.01 kWh/kg)
NOx emissions
< 120 mg/kWh
[in accordance with Regulation (EC) No. 813/2013 and the EN 267:2020 stan-
dard Class 4] < 120 mg/kWh
[in accordance with Regulation (EC) No. 813/2013 and the EN 267:2020
standard Class 4]
Control and command equipment
EBR - M14 R 15-15
Flame sensor
EBR FTEB (Black)
Ignition transformer
Fida 2P 26 kV pp-35 mA rms
Fuel oil pump
Suntec ALV 35A
Pump coil
871 T80
Electric motor
EBR 90 W, 2800 rpm
watt
90
Capacitor
Inco 4 μF, TEKNO 45T (T = top series)
Power supply
1 / 230 / 50 Ph / V / Hz
Power input (during operation) (+/- 5W)
W
183
181
Electrical protection
IP
IP40
Sound pressure level
dB(A)
65
Storage room temperature
°C
-20 ... +70
Operating temperature
°C
-10 ... +60
(1)
Reference conditions: Room temperature 20 °C – Barometric pressure 1013 mbar – Altitude 0 m.a.s.l..
m
CAUTION
(2)
The burner is suitable for use with diesel containing a biofuel blend of up to 10%. A minimum requirement for biofuel
blends (up to 10%) is that they be obtained with diesel in accordance with the applicable standards and in conformity to the
local regional regulations.