2
1.3
TECHNICAL FEATURES
FORMAT SYSTEM 25 HE
Heat output nominal (80-60°C)
kW (kcal/h)
22.7 (19,500)
Heat output nominal (50-30°C)
kW (kcal/h)
24.5 (21,160)
Heat output minimum (80-60°C)
kW (kcal/h)
8.4 (7,224)
Heat output minimum(50-30°C)
kW (kcal/h)
9.3 (8,000)
Heat input nominal
kW (kcal/h)
23.3 (20,040)
Heat input minimum
kW (kcal/h)
8.7 (7,480)
Efficiency nominal/minimum output (80-60°C)
%
97.5/97.0
Efficiency nominal/minimum output (50-30°C)
%
105.8/107.3
Seasonal efficiency rating (SEDBUK)
90.0% (A)
Termal efficiency (CEE 92/42 directive)
★★★★
Class NOx
5
Smokes temperature maximum (80-60°C)
°C
70
Smokes temperature minimum (80-60°C)
°C
63
Smokes temperature maximum (50-30°C)
°C
54
Smokes temperature minimum (50-30°C)
°C
50
Smokes flow
kg/h
39
CO
2
maximum/minimum G20
%
9.0/9.0
CO
2
maximum/minimum G31
%
10.0/9.9
Adsorbed power consumption
W
145
Electrical protection grade
IP
X4D
CE certification
n°
1312BP4098
Category
II
2H3P
Type
B
23-53
/C
13-33-43-53-83
C.H.
Maximum water head
bar
3
Maximum temperature
°C
80
Water content boiler
l
4.9
C.H. setting range
°C
20/75
Expansion vessel capacity
l
8
Expansion vessel pressure
bar
1
GAS PRESSURE END NOZZLES
Gas supply pressure G20
mbar
20
Gas supply pressure G31
mbar
37
Nozzles quantity
n°
1
Nozzles diameter G20
ø
6.0
Nozzles diameter G31
ø
4.4
C.H gas consumption nominal/minimum G20
m
3
/h
2.46/0.92
C.H. gas consumption nominal/minimum G31
kg/h
1.81/0.68
WEIGHT
kg
40
Summary of Contents for Format System 25 HE
Page 1: ...Format System 25 HE Installation and servicing instructions GB ...
Page 21: ...19 7 EXPLODED VIEWS Fig 24 Position Code Description Model 7 1 HYDRAULIC CIRCUIT ...
Page 22: ...20 Position Code Description Model 7 2 COMBUSTION CIRCUIT Fig 24 a ...
Page 23: ...21 7 3 STRUCTURAL COMPONENTS AND CONTROL REGULATIONS Position Code Description Model Fig 24 b ...
Page 25: ...Format System 25 HE User instructions GB PLEASE LEAVE THIS INSTRUCTION WITH THE USER ...
Page 26: ......