9
2.8.3
Wiring diagram
J5
J6
J9
J10
J13
J4
J8
J7
J3
90° LIMIT
THERMOSTAT
95° SMOKE
STAT
100° SAFETY
STAT
OPTIONAL
Fig. 13
NOTE:
– The room thermostat may be connected to the terminals 1-2 of the “TA” connector after having removed the link.
– To remote control the boiler connect an external clock to the terminals 1-2 (24 V) of the “TA” connector and set
the built-in clock to “constant” mode (see user instructions for details).
JUMPERS POSITION AND FEATURES
JUMPER
POSITION AND FEATURE
SUPPLY POSITION
CLOSED
OPEN
JP1 - DELAY CANCELLATION*
Ignition delay cancelled
Ignition delay operating
Open
JP2 - DIVERTOR VALVE/D.H.W. PUMP
Use with div. valve
Use with boiler pump
Closed
*
In the heating phase, the electronic board is programmed to include a burner technical delay interval of approx. 3 minutes, which occurs both
at system cold starting and at subsequent re-ignitions. The aim is to overcome the problem of repeated ignitions and turning off with very short
time intervals between. This could occur in particular in systems presenting high head losses. At each restart after the period of slow ignition,
the boiler will set itself for about 1 minute at the minimum modulation pressure, and will then move to the heating pressure value set.
Fig. 13/a
2.9
TIME PROGRAMMER (optional)
The control panel is designed to allocate a timer-program-
mer, code 8092214, which can be supplied upon request.
To fit the timer, remove the housing blanking piece from the
control panel and, with the panel open, fit the timer to the
panel using the screws supplied therein (see fig. 13/a).
Summary of Contents for Format System 25 HE
Page 1: ...Format System 25 HE Installation and servicing instructions GB ...
Page 21: ...19 7 EXPLODED VIEWS Fig 24 Position Code Description Model 7 1 HYDRAULIC CIRCUIT ...
Page 22: ...20 Position Code Description Model 7 2 COMBUSTION CIRCUIT Fig 24 a ...
Page 23: ...21 7 3 STRUCTURAL COMPONENTS AND CONTROL REGULATIONS Position Code Description Model Fig 24 b ...
Page 25: ...Format System 25 HE User instructions GB PLEASE LEAVE THIS INSTRUCTION WITH THE USER ...
Page 26: ......