81
EN
– take the combustion data reading
– press the button
y
to exit the "Chimney sweep Procedure”.
The boiler water delivery temperature will appear on the
display
– disconnect the pressure gauge, carefully close the pressure
point (6), put the control panel back to the original position
and refit the front panel (2).
Gas supply pressure
Type of gas
G20
G31
Pressure (mbar)
20
37
3.8
Gas conversion
Brava Slim HE 25 T
models can work with G20 or G31 without
the need for any mechanical conversion. Simply select
parameter”PAR 03” (see "Parameter setting and display") and
set the type of gas to be used.
If changing the type of gas to be used, carry out the entire
appliance “COMMISSIONING” phase.