69

EN

CAUTION

–  The height of the boiler is to be such that disassembly 

and maintenance interventions are facilitated.

2.9 

Plumbing connections

The  plumbing  connections  have  the  following  characteristics 

and dimensions.

95

65 65 65 65

=

=

L

M

U

G

E

R

Fig. 14

Description

Brava One OF ErP

25

M - System delivery

Ø 3/4" G

R - System return

Ø 3/4" G

U - Domestic hot water output

Ø 1/2" G

E - Domestic hot water inlet

Ø 1/2" G

G - Gas supply

Ø 3/4" G

W (mm)

450

2.9.1 

Plumbing accessories (optional)

To facilitate plumbing and gas connections to the systems, the 

accessories as shown in the table below are available and are to 

be ordered separately from the boiler.

DESCRIPTION

CODE

Installation plate

8075441

Curve kit

8075418

Curve and valve kit with connections from DIN 

to SIME

8075443

Cocks kit

8091806

Valve kit with connections from DIN to SIME

8075442

Wall mount replacement kit for other makers

8093900

Fitting protection Kit

8094531

Polyphosphate dosing kit

8101700

Dosing recharge kit

8101710

NB:

 kit instructions are supplied with the accessory itself or are 

to be found on the packaging.

2.10  Gas supply

Brava  One  OF  ErP

  boilers  leave  the  factory  specifically 

prearranged for G20 gas or G30/G31. The G20 models can be 

converted to function with G30/G31 using the "specific nozzle 

kit" (optional) provided by 

Sime

 on request separately from the 

boiler.

If changing the type of gas to be used, carry out the entire 

“GAS 

CONVERSION”

 phase of the appliance.

Boiler connection to the gas mains must be carried out in full 

compliance with installation Standards in force.

Before connecting the boiler to the gas mains, the user must 

ensure that:

–  the type of gas is correct for the appliance

–  the pipes are clean

–  the gas supply pipe is the same dimension as or greater than 

that of the boiler fitting (G3/4") and with a load loss less than 

or equal to that contemplated between the gas mains and the 

boiler.

DANGER

Once  installation  has  been  completed,  check  that 

the joints are air tight as indicated in the installation 

Standards.

CAUTION

It  is  recommended  that  the  gas  line  has  a  suitable 

filter.

2.11  Smoke outlet and combustion air inlet

Brava One OF ErP

 boilers take in combustion air from the room 

where  the  boiler  is  installed  through  the  ventilation  openings 

which must fully comply with Technical Standards.

Permitted outlets

B11BS

B11BS

Fig. 15

B11BS

Combustion air inlet into the atmosphere and smoke outlet to 

open air.

NB:

 opening for combustion air (6 cm2 x kW).

On  the  basis  of  REGULATION    (UE)  N.  813/2013  OF  THE 

COMMISSION of 2nd August 2013:

"This natural draught boiler is intended to be connected only to 

a flue shared between multiple dwellings in existing buildings 

that evacuates the residues of combustion to the outside of the 

room containing the boiler.  It draws the combustion air directly 

from  the  room  and  incorporates  a  draught  diverter.    Due  to 

lower  efficiency,  any  other  use  of  this  boiler  shall  be  avoided 

and  would  result  in  higher  energy  consumption  and  higher 

operating costs."

Summary of Contents for Brava One 25 OF ErP

Page 1: ...parede de baixa temperaturao Low temperature wall mounted boiler Навесные низкотемпературные котлы MANUAL DE INSTALACIÓN Y MANTENIMIENTO MANUAL PARA A INSTALAÇÃO E A MANUTENÇÃO INSTALLATION AND MAINTENANCE MANUAL ИНСТРУКЦИЯ ПО МОНТАЖУ И ТЕХНИЧЕСКОМУ ОБСЛУЖИВАНИЮ BRAVA ONE OF ErP EN PT ES RU ...

Page 2: ...1 3 1 Technical Data Plate 61 1 4 Structure 62 1 5 Technical features 63 1 6 Main water circuit 64 1 7 Sensors 64 1 8 Expansion vessel 64 1 9 Circulation pump 65 1 10 Control panel 65 1 11 Wiring diagram 66 2 INSTALLATION 67 2 1 Receiving the product 67 2 2 Dimensions and weight 67 2 3 Handling 67 2 4 Installation room 67 2 5 New installation or installation of a replacement appliance 68 2 6 Clean...

Page 3: ...ion operations issue a statement of compliance with national and local Technical Standards and Legislation in force RESTRICTIONS d IT IS FORBIDDEN The appliance is not to be used by children or unassisted disabled persons Do not use electrical devices or appliances such as switches electrical appliances etc if you can smell fuel If this should happen open the doors and windows to air the room clos...

Page 4: ...tically every 24 hours if no request for heat has been made the chimney sweep function lasts 15 minutes and makes the job of the qualified technician easier when measuring the parameters and combustion efficiency and when checking gas pressure at the nozzles screen display of the operating and self diagnostic parameters with error code display when the fault occurs This makes repair interventions ...

Page 5: ...NO YEAR OF MANUFACTURE SERIAL NUMBER NAME MAX USEFUL OUTPUT 50 30 C MAX OPERATING PRESSURE MAX USEFUL OUTPUT 80 60 C MAX HEAT INPUT WATER CONTENT IN BOILER FLOW RATE MAX OPERATING PRESSURE ELECTRICAL SUPPLY MAXIMUM ABSORBED POWER MAX HEAT INPUT COUNTRY OF INTENDED INSTALLTION APPLIANCE CATEGORY D H W CONTENT Fig 2 m CAUTION Tampering with removing or failing to display the identification plate or ...

Page 6: ...ition detection electrode 6 Diverter valve 7 System filling unit 8 Domestic hot water sensor 9 Control panel 10 Secondary heat exchanger 11 Gas valve 12 Domestic water filter and flow regulator 13 System relief valve 14 Boiler drain 15 System pump 16 Water pressure switch 17 Automatic bleed valve 18 Burner 19 Primary heat exchanger 20 Expansion vessel 21 Smoke outlet Fig 3 ...

Page 7: ...FORMANCE HEATING Heating seasonal energy efficiency class C Heating seasonal energy efficiency 79 Sound power db A 48 DOMESTIC HOT WATER Domestic hot water energy efficiency class B Domestic hot water energy efficiency 73 Stated domestic hot water profile load XL ELECTRICAL SPECIFICATIONS Power supply voltage V 230 Frequency Hz 50 Absorbed electrical power Qn max W 79 Absorbed electrical power at ...

Page 8: ...of Temperature Detected Resistance Examples of reading TR 75 C R 1925Ω TR 80 C R 1669Ω TR 0 C 1 C 2 C 3 C 4 C 5 C 6 C 7 C 8 C 9 C Resistance R Ω 0 C 27279 17959 12090 8313 5828 4161 3021 2229 1669 1266 973 26135 17245 11634 8016 5630 4026 2928 2164 1622 1232 25044 16563 11199 7731 5440 3897 2839 2101 1577 1199 24004 15912 10781 7458 5258 3773 2753 2040 1534 1168 23014 15289 10382 7196 5082 3653 26...

Page 9: ...these buttons for more than 30 seconds generates a fault on the display without preventing boiler operation The warning disappears when normal conditions are restored 3 DISPLAY l SUMMER This symbol appears when the boiler is operating in Summer mode or if only the domestic hot water mode is enabled via the remote control If the symbols l and n are flashing this indicates that the chimney sweep fun...

Page 10: ...re switch TA Air thermostat SE External sensor CR Remote control instead of air thermostat To connect the Air Thermostat or alternatively the Remote Control remove the bridge between terminals 5 6 Fig 8 m CAUTION Users must Use an omnipolar cut off switch disconnect switch in compliance with EN Standards Respect the connections L Live N Neutral Ensure that the special power cable is only replaced ...

Page 11: ... 26 2 3 Handling Once the packaging has been removed the appliance is to be handled manually tilting it slightly lifting it and applying pressure in the points indicated in the figure Fig 11 d IT IS FORBIDDEN DO NOT hold onto the appliance cladding but use the solid parts such as the base and the rear structure a DANGER Use suitable tools and accident protection when removing the packaging and whe...

Page 12: ...m it is recommended that the user puts a descaling additive into the water system allows the system to work with the generator active for a few days drains the dirty water from the system and flushes the system with clean water once or more than once If the old generator has already been removed or is not available replace it with a pump to circulate water in the system and then proceed as describ...

Page 13: ...ntire GAS CONVERSION phase of the appliance Boiler connection to the gas mains must be carried out in full compliance with installation Standards in force Before connecting the boiler to the gas mains the user must ensure that the type of gas is correct for the appliance the pipes are clean the gas supply pipe is the same dimension as or greater than that of the boiler fitting G3 4 and with a load...

Page 14: ...092281 m CAUTION The maintenance interventions described must ONLY be carried out the professionally qualified personnel a DANGER Before carrying out any interventions described set the main system switch to OFF close the gas valve make sure that no hot parts inside the appliance are touched OFF Fig 16 To facilitate introduction of the connection wires of the optional components into the boiler re...

Page 15: ...ns provided on the packaging of the product itself Climatic curve Delivery temperature 20 15 10 5 0 10 15 5 20 80 90 70 60 50 40 30 20 C C K 9 K 6 K 4 5 K 3 K 2 2 K 1 5 K 0 75 External temperature Fig 21 m CAUTION If there is an external sensor turn the heating knob t until the required curve K has been selected within the rangeK 0 0 K 9 0 in order to select the optimal climatic curve for the syst...

Page 16: ...alves Heating circuit open the isolation and air bleeding valves in the highest points of the system loosen the automatic bleed valve 3 open the isolation valves of the heating circuit if present open the filling valve 4 and fill the heating system until a pressure of 1 1 2 bar is shown on the display close the filling valve 4 check that there is no air in the system by bleeding all the radiators ...

Page 17: ...water valve to fill and bleed the domestic hot water circuit Boiler loosen the automatic bleed valve 3 close the heating circuit isolation valves prearranged in installation check that the filling valve 4 is closed connect a rubber hose to the boiler drain valve 7 and open it when it has fully emptied close the drain valve 7 close the automatic bleed valve 3 4 3 7 Fig 28 ...

Page 18: ...han one hot water tap The boiler will work at maximum power until the taps are closed if there is a fault the message AL will appear on the display followed by the fault code eg 06 no flame detected m CAUTION If the boiler has blocked restore the start conditions by pressing and holding the button o R for more than 3 seconds This operation can be carried out no more than 6 times close the taps ope...

Page 19: ...lar power input 0 4 1 0 tS 0 3 Gas Type Configuration 0 G20 1 G31 0 1 1 0 or 1 tS 0 4 Combustion configuration 0 sealed chamber with combustion control 1 open chamber with smoke thermostat 2 low NOx 0 2 1 1 tS 0 8 External sensor value correction 5 5 C 1 0 DOMESTIC HOT WATER HEATING tS 1 0 Boiler Antifreeze Threshold 0 10 C 1 3 tS 1 1 External Sensor Antifreeze Threshold Disabled 9 5 C 1 2 tS 1 2 ...

Page 20: ...s the button o R for approximately 3 seconds to start the appliance up again 3 5 Fault malfunction codes Type No Description AL 01 Smoke thermostat AL 02 Low water pressure in system AL 04 Domestic hot water sensor fault AL 05 Delivery sensor fault AL 06 No flame detection AL 07 Sensor or safety thermostat intervenes AL 08 Fault in the flame detection circuit AL 09 No water circulating in the syst...

Page 21: ...0 99 bar 0 1 TABLE OF COUNTER DISPLAYED Type No Description Range U M Step CO 0 0 total no of boiler operating hours 0 99 h x 1000 0 1 from 0 0 to 9 9 1 from 10 to 99 CO 0 1 total no of burner operating hours 0 99 h x 1000 0 1 from 0 0 to 9 9 1 from 10 to 99 CO 0 2 total no of burner ignitions 0 99 h x 1000 0 1 from 0 0 to 9 9 1 from 10 to 99 CO 0 3 total no faults 0 99 x 1 1 CO 0 4 total no of ti...

Page 22: ...e button once again to make the boiler operate at maximum power If the gas pressure values are correct it is possible to determine the combustion data and take a reading of the combustion efficiency as provided for by legislation in force press the button s to exit the Chimney sweep Procedure The boiler water delivery temperature will appear on the display close the taps opened previously and chec...

Page 23: ... once the value indicated in the table has been reached press the button sfor approximately 2 seconds to confirm the value which will then flash once pressandholddownthebuttonsoandsatthesametimefor approximately 6 seconds until the water delivery temperature appears on the display and the boiler shuts down starts up close the valves which were opened previously 3 8 Gas conversion Brava One OF ErP ...

Page 24: ...de is essential for the correct detection of current ionization apply the label indicating the new gas configuration on the technical data plate 11 on the inside of the front panel carry out the Automatic calibration procedure and then refit the front panel 2 securing it with the two screws 1 1 2 14 Fig 39 3 9 Automatic calibration procedure This procedure MUST BE CARRIED OUT after replacing the n...

Page 25: ...to the parameter section if not already there by pressing the buttons and o approximately 5 seconds at the same time until tS installer appears on the 2 digits of the display which alternate with 0 1 parameter number and a 2 set value keep the button pressed and scroll through the parameters until reaching parameter tS 4 9 press the button oto confirm approximately 3 seconds and access the default...

Page 26: ...ure press the button o twice the message P00 will appear on the display press the buttons or until the pressure value indicated in the table appears on the pressure gauge once the value indicated in the table has been reached press the button sfor approximately 2 seconds to confirm the value which will then flash once pressandholddownthebuttonsoandsatthesametimefor approximately 6 seconds until th...

Page 27: ...aning the heat exchanger To clean the heat exchanger remove the two screws 1 pull the front panel 2 forwards and release it from the top by lifting it 1 2 Fig 43 remove the four screws 3 and remove the front panel 4 from the combustion chamber working carefully so as not to damage the gasket or the panel insulation 3 4 5 6 Fig 44 if there is any dirt on the heat exchanger 5 fins protect the burner...

Page 28: ... input 0 tS 0 3 Gas Type Configuration 0 G20 1 G31 0 or 1 tS 0 4 Combustion configuration 0 sealed chamber with combustion control 1 open chamber with smoke thermostat 2 low NOx 1 To enter Parameter setting and display refer to the indications provided in the specific section Once the parameters in the table have been set you must carry out the Automatic calibration procedure If the gas valve and ...

Page 29: ...43 Open Therm communication fault Check the electrical connection of the remote control AL 44 Anomaly inside electronic board Replace the board AL 62 The self calibrating procedure must be carried out Carry out the self calibrating procedure see the specific section AL 72 Incorrect positioning of the delivery sensor Check that the delivery sensor is attached to the delivery pipe AL 74 Fault in the...