80
EN
4.5
Technical features
DESCRIPTION
ALU PLUS HE
360
720
1100
CERTIFICATIONS
Country of intended installation
AT - BE - CH - CY - CZ - DK - EE - ES - FI - FR - GB - GR - HU
IE - IT - LT - LV - NL - NO - PT - RO - SE - SI - SK
Fuel
G20
PIN number
1312CS6203
Category
I2H
AT - CH - CY - CZ - DK - EE - ES - FI - FR - GB - GR - HU
IE - IT - LT - LV - NL - NO - PT - RO - SE - SI - SK
12E(S)
BE
Appliance classification
B23P
Class NO
x
(*)
6 (< 56 mg/kWh)
HEATING PERFORMANCE
HEAT INPUT (**)
Nominal flow (Q
n
max)
kW
360
720
1000
Minimum flow (Q
nw
min)
kW
80
150
200
HEAT OUTPUT
Nominal (80-60°C) (P
n
max)
kW
353
705
980
Nominal (50-30°C) (P
n
max)
kW
378
756
1053
Minimum G20 (80-60°C) (P
n
min)
kW
78,4
147,3
196,4
Minimum G20 (50-30°C) (P
n
min)
kW
84,5
158
211
EFFICIENCY
Max useful efficiency (80-60°C)
%
98,1
97,9
98,0
Min useful efficiency (80-60°C)
%
98,0
98,2
98,2
Max useful efficiency (50-30°C)
%
105,0
105,0
105,3
Min useful efficiency (50-30°C)
%
105,6
105,3
105,5
Useful efficiency at 30% of load (40-30°C)
%
108,1
108,3
108,2
Losses after shutdown at 50°C
W
427
791
1054
ELECTRICAL SPECIFICATIONS
Power supply voltage
V
230
400 ~ 3N
400 ~ 3N
Frequency
Hz
50
50
50
Absorbed electrical power (Q
n
max)
W
532
1965
2134
Absorbed electrical power at (Q
n
min)
W
177
611
661
Absorbed electrical power in stand-by
W
10
15
15
Electrical protection degree
IP
X0D
COMBUSTION DATA
Smoke temperature at Max/Min flow (80-60°C)
°C
68,1 / 55,3
70,1 / 58,0
74,6 / 63,2
Smoke temperature at Max/Min flow (50-30°C)
°C
53,1 / 30,7
50,1 / 29,7
57,6 / 34,5
Smoke flow Max/Min
g/s
166 / 39
332 / 73
457 / 97
CO
2
at Max/Min flow rate (G20)
%
9,5 / 9,0
9,5 / 9,0
9,6 / 9,0
NOx measured
mg/kWh
44
43
38
NOZZLES - GAS
Number of nozzles
No.
-
-
-
Nozzle diameter (G20)
mm
-
-
-
Gas consumption at Max/Min flow rate (G20)
m
3
/h
38,08 / 8,46
76,16 / 15,87
105,78 / 21,16
Gas supply pressure (G20)
mbar
20
20
20
kPa
2
2
2
TEMPERATURE - PRESSURE
Max operating temperature (T max)
°C
85
Heating adjustment range
°C
20 - 80
Domestic hot water adjustment range
°C
-
Min./max. operating pressure (PMS)
bar
0,8 / 6
kPa
80 / 600
Water content in boiler
l
44
68
91
Loss of load water side ∆T nom (20°C)
mbar
160
160
160
Max. ∆T at min./max. power
°C
25
25
25
Water flow rate ∆T 20°C (nominal)
m
3
/h
15
31
43
Water flow rate ∆T 10°C
m
3
/h
30
62
86
Total residual head ( inlet)
Pa
200
300
250
(*)
NOx class according to UNI EN 15502-1:2015
(**)
Heat input calculated using the lower heat output (Hi)
G20 Hi.
9,45 kW/m
3
(15°C, 1013 mbar)