35
EN
12:12
20.0°C
Set auto comfort
12:12
18.0°C
Set auto reduced
12:12
[1] 07:30 - 08:30
[3] 18:00 - 22:30
[2] 12:00 - 13:30
[4]
Boiler Time Schedule
Day:
Monday
12:12
1.0
Curve slope
12:12
50%
Ambient inf.
12:12
4.0
K Reg.
12:12
0°C
Offset Z1
Set auto comfort:
desired
room temperature in
AUTO
mode
during the comfort
periods.
Curve slope:
the boiler is config-
ured for connecting to an exter-
nal air temperature sensor and
can operate with a sliding tem-
perature. The boiler’s delivery
temperature varies in relation
to the external temperature de-
pending on the selected climat-
ic curve. (
refer to the “CLIMATIC
graph).
Room influence:
the
boiler’s delivery tem-
perature can also be
influenced by the tem-
perature measured in
the room depending on
the set weight (
0% = no
influence
).
K Amb:
the boiler’s de-
livery temperature can
also be influenced by the
temperature measured
in the room depending
on the slope character-
ising the selected room
component.
(refer to the
SLOPE” graph).
Offset Z1:
It is possible to
increase or reduce the
boiler’s delivery temper-
ature by a constant value
compared to the auto-
matic adjustment with a
selected climatic curve
and room component.
Set auto reduced:
desired
room temperature in
AUTO
mode
outside the comfort
periods.