Installation, use and maintenance manual
MANUAL CODE: 6328406
Page 37 / 124
3.2
Technical features
EcoMaxi 90 ErP
Description
Unit
Heat output provided HP
kW
1,005
Total heat output
kW
2.20
Heating time (
1
)
H:M
5:30
Heating time in BOOST mode
(55°C) (
2
)
H:M
2:25
Tank dispersion
W
33
Electrical specifications
Power supply
V
1/N/230
Frequency
Hz
50
Maximum consumption HP
kW
0,270
Average consumption
kW
0,210
Resistor consu HP
kW
1,470
Electrical resistor output
kW
1.2
Type of protection
Single manual-reset safety thermostat
Operating conditions
Ambient temperature
°C
4-43
Ambient relative humidity
%
<90
Operating temperatures
Maximum temperature HP
°C
60
Maximum temperature
°C
70
Compressor
Rotary
Compressor protection
Automatic-reset thermal circuit breaker
Fan
Centrifugal
Output mouth diameter
mm
125
Number of revs
rpm
2700
Nominal air flow rate
m
3
/h
130
Max. available head
Pa
120
Motor protection
Internal automatic-reset thermal circuit breaker
Capacitor
Existing encased aluminium pipe
Refrigerant
R134a
Load
g
530
Nominal
water
storage
capacity
l
87
Max. quantity of usable hot
water Vmax(
3
)
l
95.5
Insulation
High-density polyurethane foam
Defrosting
Passive air