Installation, use and maintenance manual
MANUAL CODE: 6328406
Page 35 / 124
3
DESIGN CHARACTERISTICS
EcoMaxi 90 ErP
1
Heat pump 90 litres
2
Control panel.
3
Enamelled steel tank (boiler) in compliance
with UNI standards (90-litre capacity).
4
Heat pump unit
5
High-efficiency finned pack evaporator. The
quantity of fluid flowing into it is regulated by
a thermostatic valve (thermal expansion
valve).
6
Refrigerant refill input.
7
Centrifugal fan to recirculate the air taken
from the space.
8
Thermal expansion valve.
9
Bracket
10 Replaceable magnesium anode
11 Ventilation air output (
125 mm).
12 Hermetic rotary compressor.
13 Upper boiler probe.
14 Lower boiler probe.
15 Auxiliary electrical resistor 1.2 kW
16 Bipolar safety thermostat with manual reset
for auxiliary resistor
17 Capacitor with external covering, not in
contact with water
18 Hot water outlet connector (½”).
19 Cold water inlet connector (½”).
20 Condensate outlet (½”).
1
4
7
3
6
11
8
2
12
20
17
10
5
19
13
14
16
18
15
4
9